Storage, Transport And Packaging; Standards - Tebas INVERTER S User Manual

Pool heat pump
Hide thumbs Also See for INVERTER S:
Table of Contents

Advertisement

Storage, transport and packaging

The device should be packed and stored in an upright position as indicated on the package. Storage in
a horizontal position, even for a short time, will damage the device.
Any damage caused by improper packaging or storage is not covered warranty.
Tebas encourages customers to store the product packaging (cardboard box + polystyrene + pallet)
during the warranty period, and return the device to the manufacturer if necessary.

Standards

Compliance with CE standards
Tebas Pool Heat Pumps comply with the following regulations and standards:
Electromagnetic Compatibility Directive:
Safety requirements for low voltage equipment:
Pressure Equipment Directive:
The Noise Emissions Directive:
Harmonized standards:
Requirements for electrical connections
French assembly standard:
Security
Although this product meets all safety requirements, it may pose hazards related to: Electrically controlled
components
Moving parts, automatically started (fan)
Sharp edges (evaporator)
To avoid accidents, keep children and pets away from the device. Do not cover the appliance or place
fingers or other objects in it while it is in operation.
The device must not be put into operation when any of its plates are removed.
Pressure regulator
Tebas heat pumps are equipped with a high-pressure pressure regulator set at 38 bar.
Utility Limit Values
To ensure the correct dimensioning of the heat pump, please first contact Tebas with preparation the so-called
selection documentation (available upon request) to validate the device selection.
The inverter heat pump models are rated for operation at an air temperature of -15 ° C to + 35 ° C (5 ° F to 95 ° F),
provided that a cover is provided in the pool.
If the appliance is used in an ambient temperature below 0 °, especially in the case of high water temperatures, it is
recommended to use an electric heater (for which please ask your supplier).
Tebas is not responsible for the correct operation of products, the selection of which has not been approved by
Tebas, and which operate outside the ranges indicated above.
Correct packing and storage position.
- 4 -
2004/108/WE
2006/95/WE
97/23/WE
200/14/WE
NF EN
60335.1,2.40
NF C 15 100