INSTALLATION INSTRUCTIONS

• Installation must be performed in accordance with the requirements of CEC by
authorized personnel only.
• Cut off power supply at circuit breaker/fuse before proceeding with the installation.
This unit must be installed on the surface of a finished ceiling or suspended from the
ceiling. All the other parts required for a suspended installation are not provided with
the unit.
The unit requires a minimum mounting height of 8 feet (2.44 m) from finished floor.
For best results, do not exceed the following recommended mounting heights:
5000 watts
Keep at least 12 inches (30 cm) away from any vertical surfaces or walls.
1. Remove the external cover of the unit and
set it aside (4 screws).
2. Remove the mounting bracket (1 or 2
screws and hinges depending on the
model).
3. Screw the mounting bracket to the ceiling
and make sure the ceiling structure is strong
enough to support the unit. Make sure the
mounting bracket is installed in such a way
that the unit will sit straight and level.
4. Remove the wiring compartment cover and
set it aside.
5. Hook the slotted side of the internal
assembly to the mounting bracket. Let the
unit hang from the bracket.
6. If your model is not equipped with the
optional built-in thermostat, a wall-mounted
thermostat must be installed to control the
heater. (See thermostat instructions for
specific installation instructions)
10 feet (3.05 m)
MINIMUM
12"
(305 mm)
5
MINIMUM
12"
(305 mm)