Safety; Refrigerant; Prior To Installation - Perlick HP15 Installation Instructions Manual

Hide thumbs Also See for HP15:
Table of Contents

Advertisement

PLEASE
READ
all
instructions
attempting to install or operate the unit. Take particular
note of the DANGER, WARNING and CAUTION information
in the manual. The information is important for the safe
and efficient installation, operation and care of your Perlick
unit.
Indicates a hazard that WILL result
DANGER
in serious injury or death if
precautions are not followed.
Read and understand all information in this manual before attempting the installation. All plumbing
and electrical work must be performed by a qualified technician and conform to all applicable state

Refrigerant

Take caution when handling,
DANGER
moving and using the product to
avoid damaging the refrigerant tubing or increasing
the risk of a leak
All service work shall be
WARNING
performed by factory authorized
service personnel and all component parts shall be
replaced with like components to minimize the risk of
possible ignition due to incorrect parts or improper
service.
If service is necessary, repair work
CAUTION
must be performed by a Perlick
authorized servicer. Work done by unqualified
individuals could potentially be dangerous and will
void the warranty.
This product contains blown foam
NOTICE
insulation using blowing agent
R-611 (Methyl Formate). The foam in this product
does not contain HFC's, CFC's, or HCFC's.

Prior To Installation

Carefully inspect cabinet for hidden damage. If damage is
discovered, file your claim immediately with the transport
company. Perlick is not responsible for damage in transit.
When moving the unit, be sure to
CAUTION
protect
appropriate material to avoid damage from moving the
unit.
Do not lift unit by drawer, shelving
CAUTION
or door handles, as damage to the
unit could occur if not moved as instructed.
PERLICK RESIDENTIAL UNDERCOUNTER INSTALLATION MANUAL

SAFETY

completely
before
IMPORTANT!
and local codes.
finished
flooring
with
Indicates a hazard MAY cause
WARNING
serious
precautions are not followed.
Indicates a hazard where minor
CAUTION
or moderate injury may occur if
precautions are not followed.
Indicates that property damage
NOTICE
may
instructions are not followed.
All models covered in this user manual are manufactured
using refrigerant R600a (Isobutane). R600a is a hydrocarbon.
This refrigerant is flammable and is only allowed for use in
appliances with fulfill the requirements of UL/IEC 60335-1
and UL/IEC 60335-2-24. (To cover potential risk originated
from the use of flammable refrigerants). Consequently,
R600a is only allowed to be used in refrigerating appliances
with are designed for this refrigerant and fulfill the above-
mentioned standard.
• R600a is heavier than air. The concentration will always
be highest at the floor level.
• The explosion limits are as follows:
o Lower Limit: 1.8% by volume
o Upper Limit: 8.4% by volume
o Ignition Temperature: 460°C
To prevent personal injury, a
WARNING
minimum
required to lift the unit. Larger units may require
additional personnel.
Before moving the unit, secure the door shut with tape
to prevent door from swinging open while being moved.
Carefully move unit to installation site and place in front
of opening.
If unit has been laid on its back or
CAUTION
sides, place unit upright and allow
minimum of 24 hours before connecting power.