Safety Information (continued)
Solid fuels shall not be burned in this appliance.
The installation must conform with local codes or, in the absence of local codes, ANSIZ223. 1/NFPA54, NFPA58 Natural Gas and Propane
Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2.
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
Max. gas supply 6791.3in wc (1725kPa). Manifold pressure 11 in wc (2.74 kPa).
Prior to use, check for damaged parts such as hoses, regulators, pilots, or burners.
Inspect the fuel supply connection for signs of leakage (including the hose for the LP models) before each use of the appliance.
All leak tests should be done with a soapy solution. NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away from the appliance to avoid
burns or clothing ignition. This appliance comes with a heat shield which is an important safety component preventing contact with
Young children should be carefully supervised when they are in the area of the heater.
Any guard or other protective device removed for servicing the heater, must be replaced prior to operating the heater.
ually by
More frequent cleaning may be required as necessary. It is imperative that the control compartment, burners, and circulating air
passageways of the heater be kept clean.
Keep the ventilation opening(s) of the cylinder enclosure free and clear from debris.
The appliance should be used in a well-ventilated space and not in a building, garage or any other enclosed area.
An appliance may be installed within a shelter if the shelter meets one of the following conditions:
The shelter has walls on all sides, but with no overhead cover.
The shelter is within a partial enclosure which includes side walls. These side walls may be parallel, as in a breezeway, or at right angles
to each other.