Pressure Relief Procedure - Graco DutyMax EH 230DI Operation Manual

Hydraulic sprayer
Table of Contents

Advertisement

ti5243a
8.
Attach sprayer grounding clamp to earth
ground.
3A4401A
Safe Range (cold)
ti18197a

Pressure Relief Procedure

Follow the Pressure Relief
Procedure whenever you see this
symbol.
.
This equipment stays pressurized until
pressure is manually relieved. To help
prevent serious injury from pressurized
fluid, such as skin injection, splashing fluid
and moving parts, follow the Pressure
Relief Procedure when you stop spraying
and before cleaning, checking, or servicing
the equipment.
1.
Engage trigger lock.
2.
Turn sprayer OFF. Unplug power cord to
electric motor.
3.
Move pump valve to OFF and turn
pressure control knob fully
counterclockwise to lowest setting.
4.
Disengage trigger lock. Hold metal part
of gun firmly to side of grounded metal
pail, and trigger gun to relieve pressure.
5.
Engage trigger lock.
6.
Turn prime valve down to DRAIN
position. Leave prime valve down until
ready to spray again.
7.
If you suspect the spray tip or hose is
clogged or that pressure has not been
fully relieved:
a.
VERY SLOWLY loosen tip guard
retaining nut or hose end coupling to
relieve pressure gradually.
b.
Loosen nut or coupling completely.
c.
Clear hose or tip obstruction.