Download Print this page

Graco EH 333 HYDRA-SPRAY A Series Instructions-Parts List Manual

Electric-hydraulic airless paint sprayer
Hide thumbs Also See for EH 333 HYDRA-SPRAY A Series:

Advertisement

Quick Links

Advertisement

loading

Summary of Contents for Graco EH 333 HYDRA-SPRAY A Series

  • Page 2 ---�----- ----· WARNING HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY. FOR PROFESSIONAL USE ONLY. OBSERVE ALL WARNINGS. Read and understand all instruction manuals before operating equipment. FLUID INJECTION HAZARD . . : Spray Gun Safety Devices General Safety Be sure all gun safety devices are operating properly before This equipment generates very high fluid pressure.
  • Page 3 ° DO NOT expose Graco hose to temperatures above 180 use the lowest possible fluid pressure during flushing. ° C) or below -40 °...
  • Page 4 A VERTISSEMENT La pulverisation haute pression peut causer des blessures tres graves. Reserve exclusivement a l'usage professionnel. Observer toutes les consignes de securite. Bien lire et bien comprendre taus les manuals d'instructions avant d'utiliser le materiel. RISQUES D'INJECTION Consignes generales de securite enlever ni modifier une partie quelconque du pistolet;...
  • Page 5: Risques D�Incendie Ou D'explosion

    RISQUES EN CAS DE MAUVAISE UTILISATION DU Consignes generales de securite Pression Toute utilisation anormale de l'appareil de pulverisation au des Ce pulverisateur peut produire une PRESS/ON MAXIMUM DE accessoires comme, par exemple, la mise sous une pression TRAVAIL 2 10 bar (3000 lb/po. 2 ). S'assurer que tous les excessive, les modifications de pieces, !'utilisation de produits elements du pulverisateur et ses accessoires sont concus pour...
  • Page 6 ADVERTENCIA ROCIADO A ALTA PRESION PUEDE CAUSAR GRAVES LESIONES. SOLO PARA USO PROFESIONAL. RESPETE LOS AVISOS DE ADVERTENCIA. Lea y entienda todo el manual de instrucciones antes de manejar el equipo. PELIGRO DE INYECCJON DE FLU/DO Seguridad general modificar ninguna pieza de la pistola pues podrfa causar el Este equipo genera un fluido a una presi6n muy alta.
  • Page 7 PELIGRO POR MAL USO DEL EQUIPO;z::;m:n; ; PELIGRO DE INCEND/O EXPLOSION El flujo a alta velocidad del fluido al pasar por la bomba y Seguridad general manguera crea electricidad estatica. Si todas las partes del Cualquier mal uso del equipo pulverizador o los accesorios, tal equipo pulverizador no tienen buena tierra, pueden ocurrir como sobrepresurizacion, modificacion de piezas, uso de chispas, convirtiendo al sistema en algo peligroso.
  • Page 8 SETUP WARNING DO NOT connect a spray hose to this v alve. This is on ly a manual pres sure relieving device. Fig 1 Check Electrical Service Check Hydraulic Fluid ( Refer to Fig 1.) Push in on the two spring clips and lift the Be sure the electrical service is 120 V, shield off of the sprayer.
  • Page 10 OPE R A T I O N -------WA R NING-------, Install the Spray Tip and Guard Be sure the gun safety latch is engaged. Pressure Relief Procedure To reduce the risk of serious bodily injury, in­ -------WARNING------­ cluding fluid injection, splashing in the eyes or on ALWA YS have the tip guard in place on the spray the skin, injury from moving parts or electric shock, always follow this procedure whenever...
  • Page 12: Troubleshooting

    -- -------- Drain valve open close **When adding hydraulic fluid to sump, use only Graco approved *The electric motor has overheating protector switch which will fluid. See ACCESSORIES on page 19 for approved fluid. automatically reset on cooling. If it opens, unplug unit and let it cool for 2 to 20 minutes.
  • Page 14 Replacing Hydraulic Pump Replacing Electric Motor Unplug unit, follow the Pressure Relief Procedure If electric motor won't run and the circuit, on-off switch on page 12, take shield off and disassemble Warning, Pressur e Relief Pro­ and fuse are good, follow the unit as explained at left.
  • Page 16 · Model 226-333 with Hose and Gun Include s items 3-128, 142-148 Model 231-003 , Basic Sprayer Includ es items 3-128, 142, 144 Mode l 226-3 36 with Hose , Gun, and Suction Tube 135\ Include s items 3-148 Ref No. 2 �...
  • Page 19: How To Order Replacement Parts

    ELBOW, adapter 156-592 TUBE, riser BALL VALVE (with FKM Seals) 210-657 5000 psi (350 bar) MAXIMUM GRACO THROAT SEAL LIQUID-TSL WORKING PRESSURE Non-evaporation solvent for wet-cup. 1 /4 NPT (MBE) 206-995 1 qt (0.95 liter) 206-996 1 gal (3.8 liter)