Fault Code 04; Table 6-13. Fault Code 03; Table 6-14. Fault Code 04 - Wayne Dresser Vista 1 Series Service Manual

Blending and non-blending remote dispensers
Table of Contents

Advertisement

Probable Cause
Unit has run over preset/prepay amount.
1.
Solid state relay on solenoid drive board
shorted.
2.
Debris in diaphragm valve, actuator, or
proportional flow control valve.
3.
Defective diaphragm valve (non-blender
only).
4.
Defective actuator (non-blender only).
5.
Defective computer.
6.
Defective proportional flow control valve
(Blenders only).
Probable Cause
ROM error.
1.
Computer found defective ROM chip dur-
ing self test.
A. To clear the error message it is necessary to either cycle the power to the Duplex Computer or enter
option 99, change the data to 3 and exit option programming. Even if the problem is corrected the fault
code will continue to be displayed until one of these procedures is executed.
46
Part No. 920160 Rev A

TABLE 6-13. FAULT CODE 03.

Corrective Action
Check for 110VAC output (24VDC for blenders) to valve(s)
with handle off. If 110VAC (24VDC for blenders) is present,
replace solenoid drive board.
Check/clean all valves.
Install diaphragm service kit.
Replace actuator.
Replace computer assembly.
Replace proportional flow control valve.

TABLE 6-14. FAULT CODE 04.

Corrective Action
Clear error. If problem reoccurs replace computer assembly.
A
February 1997