February 1997
06 fault code.
Computer sensed
a valve or relay on
when it should not
be.
Check the solenoid
drive board for 110VAC
(or 24VDC blender only)
output to a valve or
relay.
Is 110VAC
(or 24VDC
blender only)
present?
YES
Replace solenoid
drive board.
Is the
problem
corrected?
NO
Replace computer.
END
FIGURE A-6. FAULT CODE 06.
NO
Replace computer.
YES
Part No. 920160 Rev A
79