Probable Cause
Reverse pulse.
1.
Disc tension is not correct.
2.
Debris holding diaphragm or actuator
open.
3.
Defective diaphragm valve or propor-
tional flow control valve (Blender only).
4.
Defective actuator (Non-Blender only).
Probable Cause
Corrupted option programming.
1.
Computer found scrambled data in option
programming.
Probable Cause
Totals data was found corrupted and reset
to zero.
1.
If error reoccurs-defective computer.
Probable Cause
Unit price data was found corrupted and
reset to zero.
1.
If error reoccurs-defective computer.
February 1997
TABLE 6-19. FAULT CODE 10 OR 21.
Corrective Action
Check for missing wave washer on pulser shaft. Install as nec-
essary.
Repair as necessary.
Install diaphragm repair kit or replace flow control valve.
Replace the actuator.
TABLE 6-20. FAULT CODE 11.
Corrective Action
Check all option programming and set Option 99 to Data 03
to clear error. Cycling power will not clear this error.
TABLE 6-21. FAULT CODE 12.
Corrective Action
Replace computer assembly.
TABLE 6-22. FAULT CODE 13.
Corrective Action
Replace computer assembly.
49
Part No. 920160 Rev A