Figure B-13. Connector And Fuse Locations On Lighted Cash/Credit Interface Board - Wayne Dresser Vista 1 Series Service Manual

Blending and non-blending remote dispensers
Table of Contents

Advertisement

J10
J5
J1 -
J2 -
J3 -
J4 -
J5 -
J6 -
J7 -
J10 - 5VDC CONNECTION TO ISB ASSEMBLY; BOTH PINS 5 VDC.
F1 -
114
Part No. 920160 Rev A
TRANSFORMER
J3
F1
J2
CONNECTION TO MAIN SALE DISPLAY.
DATA CONNECTIONS FOR THE DISPLAY CIRCUITRY
FROM DUPLEX COMPUTER CONNECTIONS J4/J5.
AC INPUT TO THE LIGHTED CASH/CREDIT
INTERFACE BOARD.
20 VDC OUTPUT TO THE PUSH TO START
SWITCH ASSEMBLY LEDS.
CONNECTION FOR THE OPERATIONAL SWITCH INPUTS.
CONNECTION FOR THE FUNCTION SWITCH INPUTS
ELECTRO-MECHANICAL TOTALIZER CONNECTION
AC INPUT FUSE (NOT FIELD REPLACEABLE)
FIGURE B-13. CONNECTOR AND FUSE LOCATIONS ON
LIGHTED CASH/CREDIT INTERFACE BOARD.
TRANSFORMER
ON PUSH-TO-
START MODELS
ONLY
J4
J1
J7
J6
February 1997