Figure A-9. Fault Code 10 Or 21 - Wayne Dresser Vista 1 Series Service Manual
Blending and non-blending remote dispensers
Hide thumbs
1
2
3
4
Table Of Contents
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
page
of
150
Go
/
150
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
82
Part No. 920160 Rev A
10 or 21
fault code.
Reverse pulse error.
Error
occurs while
dispensing blend
YES
at proportional
blender?
NO
While
dispensing
feedstock at
YES
proportional
blender?
NO
1
Is there
enough tension
NO
on the pulser
disc?
YES
Is the
pulser shaft
NO
aligned with the
drive gear?
YES
Ensure that all air
is purged from the
underground
system.
2
Replace the
computer.
END
FIGURE A-9. FAULT CODE 10 OR 21.
Ensure that both
submersible pumps
are operating at equal
bypass pressures.
Correct as necessary.
Check for leaking
flow control valves
on the opposite
side feedstock from
that being dispensed.
Correct as necessary.
Install wave washer
if one is not present.
Align the pulser shaft
with the meter drive
gear.
Is the
problem
NO
corrected?
YES
Is the
YES
problem
corrected?
NO
1
Is the
problem
YES
corrected?
NO
1
Is the
problem
NO
2
corrected?
YES
February 1997
Table of
Contents
Previous
Page
Next
Page
1
...
89
90
91
92
93
94
95
96
Show Quick Links
Quick Links:
Troubleshooting Guide
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Troubleshooting
TROUBLESHOOTING GUIDE
51
APPENDIX A. TROUBLESHOOTING FLOWCHARTS
83
Related Manuals for Wayne Dresser Vista 1 Series
Dispenser Wayne Vista Series Service
Blending and non-blending suction pumps and remote dispensers (166 pages)
Dispenser Wayne 3/VISTA series Service Manual
Blending and non-blending dispensers (83 pages)
Dispenser WAYNE GLOBAL VISTA CNG Instruction Manual
(28 pages)
Dispenser Wayne Ovation Installation & Operation Manual
(88 pages)
Dispenser Wayne Reliance G6101D Installation & Operation Manual
S1 ast mechanical registration fleet dispensers (44 pages)
Related Content for Wayne Dresser Vista 1 Series
Vista Series Flowchart A-8. 10 Or 21 Fault Code
Wayne Vista Series
Vista Series Fault Code 10
Wayne Vista Series
Reliance G6101D 10:1 Reed Pulser Option
Wayne Reliance G6101D
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL