Prerequisites for installing a pellet boiler

5
Prerequisites for installing a pellet boiler
You must fulfill the following conditions before operating a fully automatic pellet boiler.

5.1 Central heating room

The pellet boiler is installed in the central heating room.
Safety instructions for the heating room
1.
Risk of fire
Do not store flammable materials or liquids in the vicini-
ty of the pellet boiler.
Do not permit unauthorised persons to enter the central
heating room - children are to be kept out.
Always close the boiler door.
Air supply and ventilation of central heating room
2.
The central heating room must be fitted with air supply and ventilation openings (at least 200cm2). Legis-
lation in your country must be observed.
Combustion air supply
3.
The pellet boiler needs a supply of combustion air.
Never operate the pellet boiler if the air intake openings are partially or completely closed.
Contaminated combustion air can cause damage to the pellet boiler. Never store of use cleaning deter-
gents containing chlorine, nitrobenzene or halogen in the room where the heating system is installed, if
combustion air is drawn directly from the room.
Do not hang out washing in the central heating room.
Prevent dust from collecting at the combustion air intake to the pellet boiler.
4.
Damage due to frost and humid air
The central heating room must be frost-proof to ensure trouble-free operation of the heating system. The
temperature of the central heating room must not fall below –3°C and must not exceed +30°C. The air hu-
midity in the central heating room must not exceed 70%.
Danger for animals
5.
Make sure that household pets and other small animals cannot enter the central heating room. Fit mesh
over any openings.
Flooding
6.
If there is a risk of flooding, switch off the pellet boiler in good time and disconnect from the power supply
before water enters the central heating room. You must have all components that come into contact with
water replaced, before you start up the pellet boiler again.
Cleaning
7.
Clean the flue gas tube and chimney regularly.
Oxidation of chimney
Do not use metal brushes to clean chimneys made of
stainless steel.
Legislation in your country must be observed.