Setting
Setting
Relation
Group
name
DEF
d
DEF
d1
Defrosting interval
Defrost type 1= FAN, 2=ELEC, 3=Automatic (see d11) 4=
DEF
d2
HOTGAS
Defrost reference 0= time, 1=combined time and room sensor,
DEF
d3
2= combined time and evap. temperature., 3= combined time
and Id1 activation, 4 = evap. Temp
DEF
d4
Dripping duration
DEF
d5
Defrost end temp. (P2 sensor)
DEF
d6
Defrost duration time max.
Defrost end temp differential above SP, measured on Room
sensor (P1) if F0 = 0 and S5 = 0
DEF
d10
Actual P1 temperature ≥
(only if d2 =1 and d3 = 1)
Display reed out during defrosting
0 = Actual room temperature
1 = ‐ d ‐
DEF
d12
2 = dEF
3 = If room temperature is below SP + C1 at time of defrost
start, SP is displayed. If room temperature is above SP + C1 at
time of defrost start, actual temp at defrost start is displayed.
DEF
d13
Delay in display temp update after end defrost if d12 = 3
Time ˂
DEF
d14
d2 = 1 and d3 = 3)
DEF
d15
Maximum number of consecutive skipped defrosts
Parameter name
SP + d10 = defrost end
since Id1 activation to skip defrosting cycle (only if
d14
Adjustment
Unit
Range
resolution
4, 6, 8 or
Hours
‐
12
1, 2, 3 or
NUMERIC
N/A
4
NUMERIC
1 or 2
N/A
Min
0 to 5
1
°
0 to 12
1
Min
0 to 60
1
K
0 to 5
1
0, 1, 2 or
NUMERIC
N/A
3
Min
0 to 60
5
Min
0 to 180
10
NUMERIC
0 to 5
1
21
Default
Default
Default
Default
K
KG
F
FG
6
6
6
6
1
1
2
2
1
1
2
2
0
0
2
2
N/A
N/A
10
10
30
30
30
30
2
2
N/A
N/A
3
3
3
3
15
15
30
30
30
30
N/A
N/A
2
2
N/A
N/A