Connecting To A Modem - Brainboxes PS-307 User Manual

Parallel, serial and ieee interface
Table of Contents

Advertisement

RS232 Port
when it it is unable to receive any more data. The sending
device reads DTR on its CTS and DCD pins. It should
stop sending when CTS goes false.
4)
Connect the PSI RTS pin 4, to the PC DSR line, pin 6.
Also, connect up the PC RTS line, pin 4, to the PSI DSR
line, pin 6.
This RTS line is used to let the other device know that it
is ready for data exchange.

Connecting To A Modem.

______________________ _
If you are connecting a MODEM to the PSI BOX then
you will not need a cross over cable and a straight through cable
connecting pins 1-8 and 20 is all that is required.
Figure 5-7. The RS232 Port Pin Outs.
________________________________
___
PIN
SIGNAL
______
1
GROUND
2
TxD TRANSMITTED DATA
3
RXD RECEIVED DATA
4
RTS REQUEST TO SEND
5
CTS CLEAR TO SEND
6
DSR DATA SET READY
7
GROUND
8
DCD DATA CARRIER DETECT
20
DTR DATA TERMINAL READY
9-19
NO CONNECTION
21-25
NO CONNECTION
Chapter 5
PSI BOX Reference
_________
DIRECTION
N/A
OUTPUT FROM PSI BOX
INPUT TO PSI BOX
OUTPUT FROM PSI BOX
INPUT TO PSI BOX
INPUT TO PSI BOX
N/A
INPUT TO PSI BOX
OUTPUT FROM PSI BOX