iNSTallaTiON

installation
Note
f Install the appliance flush to the wall. The wall must
f
have sufficient load bearing capacity.
7.2

Minimum clearances

≥50
f Maintain the minimum clearances to ensure trouble-free op-
f
eration of the appliance and facilitate maintenance work.
7.3

Water installation

Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
f Flush the water line thoroughly.
f
Taps
Use appropriate pressure taps. Open vented taps are not per-
missible.
Permissible water line materials
- Cold water inlet line:
Pipes made from galvanised steel, stainless steel, copper or
plastic
- DHW outlet line:
Pipes made from stainless steel, copper or plastic
Material losses
!
If plastic pipework systems are used, take into account
the maximum inlet temperature and the maximum per-
missible pressure.
Flow rate
f Ensure that the flow rate for switching on the appliance is
f
achieved.
f If the required flow rate is not achieved when the draw-off
f
valve is fully open, remove the flow limiter from the cold
water inlet.
If required, the pressure in the water installation can also be
raised.
www.stiebel-eltron.com
≥50
8.
Installation
factory settings
Internal anti-scalding protection in °C
Connected load in kW
Standard installation
Electrical connection from below, installa-
tion on finished walls
Water connection, installation on finished
walls
For further installation options, see chapter "Alternative instal-
lation methods".
8.1

Standard installation on finished walls

Opening the appliance
f Open the appliance by undoing the screw and lifting up the
f
appliance cover.
Preparing the power cable
A
f Prepare the power cable.
f
Position on finished walls
Bottom, centre
Bottom, left side of appliance
Bottom, right side of appliance
Top, right side of appliance
Position on unfinished walls
Bottom
Top
DCE-S 6/8
DCE-S 10/12
Plus
Plus
60
60
@ 220 V
8.0
12.0
@ 230 V
8.7
13.1
@ 240 V
9.6
14.3
DCE-S 6/8
DCE-S 10/12
Plus
Plus
x
x
x
x
B
Dimension a
Dimension B
30
120
20
90
20
90
20
80
Dimension a
Dimension B
20
90
20
80
DCE-S Plus |