Installation; Electrical Connection; Operation - Galvamet Edge Installation, Operating And Maintenance Instructions

230-240 vac 50 hz
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS FOR COOKER HOOD
GB
Exhausting cooker hood. The equipment is constructed in accordance with European Standards and with the requirements included in the following
Directives: 2006/95EC ( Low Voltage Directive), 2004/108 (Electromagnetic Compatibility).
WARNINGS
The present instruction manual is an integral part of the appliance itself,
therefore it must be carefully kept and ALWAYS accompany it, even in
case of its assignment to another owner or user or in case the cooker
hood is moved to another installation plant.
Make sure that the voltage (V) and frequency (Hz) indicated on the data
plate inside the unit match those available at the installation site. Any
eventual adjustment to the electrical system, which may be necessary
to install the cooker hood, must be carried out only by competent
people.
Any repair carried out by no competent people may cause damages.
For any repair or needed technical action make reference to a
Technical Assistance Center, which is authorized to carry out the
replacement of the spare parts. Always make sure that all the electrical
parts (lights, exhaustion unit) are disconnected when the appliance is
not in use. By storms take off the main switch of the house electrical
system.
The using of the cooker hood must not be other than the use of
exhausting units for cooking damps on domestic kitchens.
The manufacturer does not accept any liability for damages caused by
people, animals or things, by installation and maintenance mistakes or
by any illegitimate use.
We remind that the use of products functioning with electrical energy
implies the observance of some essential security rules, as follows:
This equipment is not intended for people (children included)
with reduced mental or motor capacities, with lack of
experience or knowledge, unless they are supervised or
unless a person responsible for their security, gives them
instructions regarding the use of the equipment. Children
must be supervised in order to be sure that they do not play
with the equipment.
Any cleaning action is forbidden if the appliance hasn't been
disconnected from the main power supply and if the main
switch of the house electrical system is not off. If cleaning is
not carried out according to these instructions, a fire may
break out.
Do not pull, take off or twist the cable coming out from the
appliance, even though this has been disconnected from the
main power supply.
Do not sprinkle or throw any water directly on the appliance.
Do not stick any sharp tool inside the exhausting holes and
into the air discharge.
Do not take out the filters in order to reach the internal sides
of the appliance in case the main switch of the house
electrical system is not off.
Do not singe or flambé directly underneath the cooker hood.
Take particular care when frying to ensure that the oil does
not catch fire.
CAUTION: Accessible parts may become hot when used
with cooking appliances.
USE
This cooker hood can be employed as exhausting or filtering.
Exhausting (external evacuation). Kitchen smokes are driven outside
through a flue (not provided with the hood) joined to the exhaust pipe
flue connector. This pipe must not under any circumstances be
connected to cooker, boiler or burner exhaust pipes, etc.
The use of pipes and holes on the wall with a smaller diameter than the
output of the motor will cause a decrease in suction performance and
an increased of the noise level.
Use as short as possible tubes and with few curves.
Use pipes with smooth internal surfaces.
Filtering (inside recycling). The fumes pass through activated carbon
filters (supplied with the hood) to be purified and recycled into the
kitchen.

INSTALLATION

Read the instruction manual before installing and/or using the hood.
The minimum distance between the supporting surface of the cooking
hob and the lowest part of the range hood must be not less than 65cm
with a gas hob. If the mounting instructions of the gas hob indicate a
wider distance, respect it.
The unit must not be mounted above cookers fitted with top
radiant plate.
For proper operation it is recommended to install the product at a
distance of 200 – 210 cm from the floor.
Respect all the air discharge regulations.
MOD. EDGE 230-240 Vac - 50 Hz
The air must not be discharged in a pipe used to discharge exhaust
fumes produced by gas-fed equipments or fuel-fed equipments (this
does not apply to filtering hoods).
The room must be adequately ventilated when the hoods is used
together with other gas or fuel equipments.
For an easy access, it is advisable to move possible furniture under the
installation area.
Installation of the hood
The hood is equipped with all the necessary fastenings for its
installation, which are suitable for most surfaces. Verify that the
installation surface is strong.
Installation must be carried out by qualified installers according to
present regulations.
EXHAUSTING:
The hood can be installed in two different ways:
FILTERING:
Assemble the box combining the four inox walls and fixing them
manually folding the inox tabs. Fig. 9
Fix the box to the hood with the provided screws. Fig. 10
Adjust the height of the two mounting brackets at 162mm. Fig. 11
Install the hood to the ceiling following the visual instructions Fig. 12-
13-14-15
The motor can also be positioned away from the hood at a distance not
longer than 7m. In this case the hood can only be used in the
exhausting version. If the motor is installed on the wall it is prohibited to
have the air outlet on the side. Fig. 16

ELECTRICAL CONNECTION

This equipment must be connected to a grounding plant.
Two types of electrical connection can be used:
Refer to the plate inside the hood for the mains voltage and frequency
If the power cable is damaged, it must be replaced by the manufacturer
or by its service agent or a qualified person in order to avoid any risk.

OPERATION

The hood is supplied with a multispeed motor.
The hood should be run at low speed under normal conditions and at
higher speeds only when there is a heavy build-up of fumes or odours.
Ideally, the hood should be switched on as soon as cooking is started
and then kept on until all odours have been eliminated.
Remote Control Functions
When turned on, the engine is positioned at the second speed. The
motor speed is indicated by the lighting of the respective green LED
(ref. pos. 1-2-3-4). At the fourth speed (intensive, ref. pos. 4), the LED
flashes and after 5 minutes the motor returns to the third speed
automatically.
Fixed with the motor directly on the ceiling (possible only when
the distance between the ceiling and the false ceiling is between
200 and 270mm). Follow the visual instructions Fig. 1-2-3-4-5-6.
Fixed with the motor directly on the false ceiling. Follow the
visual instructions Fig. 7-8.
1.
Using a standard plug to be connected to the power cable
and inserted in a mains socket which must be accessible (so that
the plug can be disconnected when servicing is carried out).
Make sure that the plug is accessible also after the complete
installation of the equipment.
2.
By means of a fixed mains connection, fitting a bipolar
switch, which ensures the disconnection, with an opening
distance of the contacts allowing a complete disconnection on
the conditions of the overvoltage III category, according to
installation regulations. The ground connection (yellow-green
wire) must not be interrupted.
ratings.
On-Off motor
On-Off Light
Increase fan speed
Reduce fan speed

Advertisement

Table of Contents