Operating altitude : 2000m (6562 ft)
Conductor Size : 27mm diameter.
Pollution degree : 2
EMC : EN 61326-1
Shock vibration :
Sinusoidal vibration per MIL-T-28800E
(5 ~ 55 Hz, 3g maximum).
Drop Protection :
4 feet drop to hardwood on concrete floor.
Dimensions (W x H x D) :
56mm x 188mm x 28mm
Weight : 225g including battery.
Accessories : Battery (installed), carrying
case, Test lead and User manual.

1-3 Electrical Specifications

Accuracy is ±(% reading + number of digits)
at 23°C ± 5°C < 80%RH.
Temperature coefficient :
Add 0.2 x (Specified accuracy) / °C, < 18°C,
> 28°C .
ACV
Range
Resolution
Accuracy
400.0V
0.1V
± (0.9%+ 5 D)
600V
1V
Frequency Response : 50 ~ 500Hz
AC Conversion Type :
3031 : AC Conversion are average sensing
RMS indication calibrated to the RMS value
of a sine wave input.
3035 :
AC Conversions are ac-acoupled, true RMS
responding, calibrated to the RMS value of a
sine wave input. Accuracies are given for