102 en | Troubleshooting
Malfunction
The unit does not
report an alarm.
The unit is not opera-
tional after firmware
upload.
No LUNs are dis-
played after connect-
ing to the iSCSI
server.
LUN FAIL is dis-
played under a node
after connecting to
the iSCSI server.
LUN mapping not
possible.
V 2.5 | 2007.6
Possible causes
Alarm source is not
selected.
No alarm response speci-
fied.
Power failure during pro-
gramming by the update file.
Incorrect update file.
iSCSI server configuration
has incorrect LUN mapping.
The LUN list could not be
accessed because it was
assigned to the wrong net-
work interface.
The iSCSI system does not
support the use of initiator
identification.
Operating Instructions
Solution
Select possible alarm sources on
Alarm sources
the
page.
Specify the desired alarm
Alarm connec-
response on the
tions
configuration page, if neces-
sary change the IP address.
Have the unit checked by Cus-
tomer Service and replace if neces-
sary.
Enter the IP address followed by /
main.htm in your web browser
and repeat the upload.
Check iSCSI server configuration
and reconnect.
Check iSCSI server configuration
and reconnect.
Delete the identity on the iSCSI-
parameter configuration page.
Bosch Security Systems
Dinion IP
configuration