Panasonic FX-301 Series Instruction Manual page 7

Photoelectric sensor
Hide thumbs Also See for FX-301 Series:
Table of Contents

Advertisement

PRO3
PRO3 mode can load configuration settings from the data bank, i.e.
"channel", and save configuration settings to the data bank.
Mode
Setting
Description
Press the jog switch to load configuration
settings from the respective channel (1, 2 or
3). When the display blinks
the jog switch to confirm.
Press the jog switch to save configuration
settings to the respective channel (1, 2 or 3).
When the display blinks
jog switch to confirm.
PRO4
PRO4 mode is used mainly to configure communication with sub units.
Communication takes place only in the direction shown in the following
diagram.
Direction of communication
1
2
3
4
5
6
7
When copying data from the 4th unit, it will be copied to units
5 and up, but not to units 1-3.
When copying data from the 1st unit, it will be copied to all sub units.
Mode
Setting
Description
_
Except for data bank information, settings
are copied to the sub units.
Press the jog switch to load the configuration
settings from each amplifier's respective
remote channel (1, 2 or 3). When the display
blinks
firm.
Press the jog switch so that each amplfier
saves its configuration settings to the
respective remote channel (1, 2 or 3). When
the display blinks
switch to confirm.
Communication lock function OFF.
You can load and save settings remotely.
Communication lock function ON.
You cannot load or save settings remotely.
, press the
8
9
10
11
12
13
14
, press the jog switch to con-
, press the jog
Mode
Setting
, press
PRO5
PRO5 mode allows you to make multiple settings at once based on codes,
adjust lock functions and reset the unit.
The 0-ADJ setting function was removed in May, 2005.
Mode
Setting
( F a c t o r y
setting.)
15
16
Code setting table
1st digit
Response
Code
Hysteresis
time
Std
H-02
Std
H-03
Std
H-01
Lon9
H-02
Lon9
H-03
Lon9
H-01
FASt
H-02
FASt
H-03
FASt
H-01
S-d
H-02
7
Description
Back-up ON.
Back-up OFF.
Prevents frequent overwriting of data in the
EEPROM: the threshold values are not
stored in the EEPROM when teaching via
external input, e.g. with the FX-CH2 external
input unit for digital sensors.
Description
Choose a code from the code setting table
(See "Code setting table" on page 7.)
If any other code is entered, ' - ' is displayed.
1 Press the jog switch to select the first digit
in the code.
2 Turn the jog switch to select a number.
3 Press the jog switch to confirm the
number and move to the next digit.
Adjust lock ON.
You cannot adjust the threshold value in
RUN mode.
Adjust lock OFF.
You can adjust the threshold value in RUN
mode.
Press the jog switch to reset the unit.
Press <MODE> to cancel.
2nd digit
3rd digit
L-ON/
Adjust
Code
Display
Code
D-ON
lock
operation
ON
L-On
digt
ON
L-On
---P
ON
L-On
PHLd
ON
L-On
bHLd
OFF
d-On
digt
OFF
d-On
---P
OFF
d-On
PHLd
OFF
d-On
bHLd
4th digit
Timer
Code
Timer
OFF
non
1ms
ofd
3ms
ond
5ms
osd
10ms
non
30ms
ofd
50ms
ond
100ms
osd
300ms
500ms
1s
2s
3s
4s
5s

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx-301pFx-301-c1Fx-301p-c1

Table of Contents