B. 2
RF RE CEI VE R
B. 2.1
Dem od ul at ion Sel ect io ns
O FF , A M , F M , F M 50 µs , F M 7 5 µ s, F M 7 50 µs , A M U S B, AM L S B
B. 2.2
Fr equ ency R an ge (U sab le f ro m 100 kH z)
10 M H z t o 1 .0 5 G H z (39 0 1, 39 20 S tan d ard )
10 M H z t o 2 .7 G Hz (3 90 2 , 3 92 0 F re q Ex ten s ion O pt ion [3 90 XO P T 05 8] )
B. 2.3
Sens it ivit y
B. 2. 3. A
P re-A mp O FF
<- 10 0 dB m (10 dB S IN A D , F M, 25 k H z, 1 kH z ra te , 6 k H z FM D ev iati on , 3 0 0 Hz t o 3.4 kH z
AF F ilte r)
B. 2. 3. B
P re-A mp O N
<- 11 3 dB m (10 dB S IN A D , F M, 25 k H z, 1 kH z ra te , 6 k H z FM D ev iati on , 3 0 0 Hz t o 3.4 kH z
AF F ilte r, P re -A m p O n )
B. 2.4
Select ivi t y
B. 2. 4. A
I F Ban d wi d th
6. 25 , 8 .33 , 1 0, 12 .5 , 25 , 3 0, 10 0, 30 0 kH z Filte rs
B. 2.5
Dem od Ou t pu t L evel
B. 2. 5. A
FM
2. 5 V rm s 1 0% ( for de via tio n 1/ 2 o f s ele ct ed B W; 2 5 k H z B W s am e ou tp ut lev el as 30
kH z BW)
B. 2. 5. B
AM
2. 25 V rm s 10 % (fo r 1 00 % A M )