RF G EN ERAT OR ( CO NT )
B. 1.4
M o du lat io n
B. 1. 4. A
S el ecti o ns
O FF , A M , F M , F M 50 µs , F M 7 5 µ s, F M 7 50 µs , A M U S B, AM L S B
B. 1. 4. B
I nter na l F M
B. 1. 4. B. 1
RF R an ge (Us ab le fro m 1 00 k Hz)
10 M H z t o 1 .0 5 G H z (39 0 1, 39 20 , 3 92 0B S ta nd ar d)
*3 92 0B re fe r to P ha se N o ise S pe cific at ion s f or fre q > 1. 0 G H z
10 M H z t o 2 .7 G Hz (3 90 2 , 3 92 0, 39 20 B Fr eq E xte ns ion O p tion [3 9 0X O PT 0 58 ])
B. 1. 4. B. 2
Dev ia tio n
0 .00 1 to  1 50 kH z , O F F
B. 1. 4. B. 3
Acc ur acy
3% (Fr om 1 k H z to 1 0 0 k H z d ev iat ion , 2 0 H z to 15 k Hz ra te)
B. 1. 4. B. 4
Res ol u tio n
1 Hz
B. 1. 4. B. 5
Dev ia tio n R ate
20 H z t o 1 5 kH z
B. 1. 4. B. 6
Wa vefo rm
Si ne , S qu are , T ria ng le , R am p , D ig ital Co de d S qu elc h (D CS ), Du a l To n e M u ltip le
Fr eq ue nc y (D TM F )
B. 1. 4. B. 7
TH D
<1 % (1 k Hz ra te , 6 kH z d e via tio n, 3 0 0 H z to 3 k H z B W, S in e)