Fujitsu WATERSTAGE UTW-SCB A Series Operation Manual page 11

Control box inverter heat pump
Table of Contents

Advertisement

Control Box
Line
Function
Domestic Hot Water (Only with the DHW kit option)
1610
Nominal setpoint
The backup electrical system is required to reach this level.
1612
Reduced setpoint
Swimming pool (Only with swimming pool kit option)
2056
Setpoint source heating
Fault
6711
Reset HP
Service / Special operation
7141
Emergency operation
Off : The heat pump does not use the boiler connection when a fault occurs (error 370).
On : The heat pump uses the boiler connection when a fault occurs (error 370).
In the "On" position, the energy costs can be onerous if the error is not eliminated.
Diagnostics heat generation
8410
Return temp HP
Setpoint (return) HP
8412
Flow temp HP
Setpoint (flow) HP
8413
Compressor modulation
Diagnostics consumers
8700
Outdside temperature
8701
Outside temp min
Reset ? (No, Yes)
8702
Outside temp max
Reset ? (No, Yes)
8740
Room temperature 1
Room setpoint 1
8743
Flow temperature 1
Flow temperature setpoint 1
8756
Flow temp cooling 1
Flow temp setpoint cooling 1
8830
DHW (domestic hot water) temperature
DHW temperature setpoint
Operation manual "1408 - EN"
Setting range or display
Reduced setting (line 1612)...
to 65 °C
8 °C...
to Nominal setpoint (line 1610)
8... 35 °C
No, Yes
Off, On
0... 140 °C
0... 140 °C
0... 140 °C
0... 140 °C
0... 100%
-50... 50 °C
-50... 50 °C
-50... 50 °C
0... 50 °C
4... 35 °C
0... 140 °C
0... 140 °C
0... 140 °C
0... 140 °C
0... 140 °C
5... 80 °C
Setting
Basic setting
increment
1
50 °C
1
25 °C
22 °C
No
Off
20 °C
20 °C
50 °C
50 °C
0
0
50 °C
- 11 -