Fujitsu WATERSTAGE UTW-SCB A Series Operation Manual page 10

Control box inverter heat pump
Table of Contents

Advertisement

Control Box
Line
Function
Time programme 4 / DHW
If the installation is fitted with a DHW tank. (Only with the DHW kit option).
560
Pre-selection (Day / Week)
Mon-Sun Mon-Fri Sat-Sun Monday Tuesday...
561
1
phase On (start)
st
562
1
phase Off (end)
st
563
2
phase On (start)
nd
564
2
phase Off (end)
nd
565
3
phase On (start)
rd
566
3
phase Off (end)
rd
576
Default values
Yes + OK : The default values memorised in the regulator replace and cancel the customised heating programmes.
Your customised settings are therefore lost.
Time programme 5 / Cooling
600
Pre-selection (Day / Week)
Mon-Sun Mon-Fri Sat-Sun Monday Tuesday...
601
1
phase On (start)
st
602
1
phase Off (end)
st
603
2
phase On (start)
nd
604
2
phase Off (end)
nd
605
3
phase On (start)
rd
606
3
phase Off (end)
rd
616
Default values
Yes + OK : The default values memorised in the regulator replace and cancel the customised heating programmes.
Your customised settings are therefore lost.
Holidays, heating circuit 1
641
Preselection
642
Start (Day / Month)
643
End (Day / Month)
648
Operating level (during the holidays)
Heating, circuit 1
710
Comfort heating setpoint
712
Reduced setpoint
714
Frost protection setpoint
Cooling circuit 1
901
Operating mode
902
Comfort cooling setpoint
907
Release
If the installation is fitted with a DHW tank, set the parameter 907 to " Time program 5 / Cooling"
(In order to activate cooling only during the day and leave the DHW system to operate during the night).
- 10 -
Setting range or display
00:00... --:--
00:00... --:--
00:00... --:--
00:00... --:--
00:00... --:--
00:00... --:--
No, Yes
00:00... --:--
00:00... --:--
00:00... --:--
00:00... --:--
00:00... --:--
00:00... --:--
No, Yes
Period 1 to 8
01.01... 31.12
01.01... 31.12
Frost protection, Reduced
from reduced setpoint to 35°C
from frost protection setpoint...
to comfort setpoint
from 4°C...
to reduced setpoint
Off, Automatic
17... 40 °C
24h/day, Time program HC,
Time program 5 / Cooling
Setting
Basic setting
increment
Mon-Sun
10 min
00:00
10 min
05:00
10 min
--:--
10 min
--:--
10 min
--:--
10 min
--:--
No
Mon-Sun
10 min
8:00
10 min
20:00
10 min
--:--
10 min
--:--
10 min
--:--
10 min
--:--
No
Period 1
1
1
Frost
protection
0,5 °C
20 °C
0,5 °C
18 °C
0,5 °C
8 °C
Off
0,5 °C
24 °C
Time
program 5
Operation manual "1408 - EN"