Download Print this page

Seagate Lyve Rack R1 Installation Site Requirements Checklist page 2

Hide thumbs Also See for Lyve Rack R1:

Advertisement

The management interfaces and the BMC
interfaces on both servers could be on different
subnets or VLANs (should higher protection for
the BMC interface be desired). If this approach
is used, the Management network must be
routable to the BMC network and there must
not be any IPMI filtering between these two
subnets.
The Management Virtual IP must be on the
same subnet as the physical interfaces for the
Management network.
1 x static IP is required for the Management
Virtual IP.
Physical interfaces for each server are
configured using DHCP static allocation (aka
DHCP reservation). The Information sheet
supplied with each Lyve Rack R1 unit
documents the pertinent MAC addresses.
High Speed
IEEE 802.3bg (QSFP28) compatible switch
Data
25GbE, 50GbE, or 100GbE.
Networking
(Public data
1 port required if supplied Y-cable is used and
interface)
the port must be configured in breakout mode.
Alternatively, if it is desired to connect the
servers to two separate High Speed Data
Switches for redundancy, direct connect cables
(not supplied) may be used. In this scenario,
the ports on both switches must be configured
on the same subnet.
The Data Virtual IP must be on the same
subnet as the physical interfaces for the Data
network.
The High Speed Data interfaces and the High
Speed Data virtual IP must be on a different
subnet to the management interfaces and
management virtual IP.
1 x static IP is required for the Data Virtual IP.
Physical interfaces for each server are
configured using DHCP static allocation (see
Information sheet for MAC addresses).
S3 data sources and clients must be routable to
the subnet on which the data VIP is configured.
DHCP server
Lyve Rack R1 currently supports DHCP server
(Optional if
and static IP configurations.
static IP
The DHCP server configuration supports:
configuration
is used)
IP allocation (static DHCP lease) based on
configuring Reserved Addresses to
correspond to MAC addresses (provided
on information sheet).
Anything that supports QSFP28
connections.
You must procure the 100GbE to dual
50GbE Y-cable or two 100GbE to
100GbE separate cables.
2
7
Page
of
Seagate PN 1104485-01_rD

Advertisement

loading