Omega FTB380 Series User Manual

Aluminum turbine flowmeters

Advertisement

Quick Links

FTB380 SERIES
Aluminum Turbine Flowmeters

Advertisement

Table of Contents
loading

Summary of Contents for Omega FTB380 Series

  • Page 1 FTB380 SERIES Aluminum Turbine Flowmeters...
  • Page 3: Table Of Contents

    For best results, take the time to fully ac- TABLE OF CONTENTS quaint yourself with all information about all components of your FTB380 Series Turbine General Information ........1 Meter System prior to installation and use. If Product Description ........2 you need assistance, contact the Omega Flow Installation ...........
  • Page 4: Product Description

    PRODUCT DESCRIPTION date is printed on the bottom of the turbine. FTB380 Series Turbines are identified by the SN = Serial Number, a 7-8 digit number that internal diameter of the inlet and outlet. identifies this particular turbine.
  • Page 5: Connections

    Flow altering devices such as elbows, valves, All Series FTB380 turbines are Factory Mu- and reducers can affect accuracy. The fol- tual Approved and carry a Class 1, Division 1 lowing recommended guidelines are given to Approval for hazardous environments. They enhance accuracy and maximize performance.
  • Page 6: Operation

    DISPLAY button for 3 seconds to reset the the screws. Batch Total to zero. If you ordered the FTB380 Series turbine with When fluid is flowing through the meter, a an accessory module, please review and thor- small propeller icon is highlighted.
  • Page 7: Calibration

    The “field” calibration may be set by the user, Field Calibration Procedures and can be changed or modified at any time (Dispense/Display Method) using the calibration procedure described in 1. To field calibrate, press and hold the CALI- the Calibration Section. Totals or flowrate BRATE and DISPLAY buttons for about derived from the field calibration are invoked 3 seconds until you see FLdCAL.
  • Page 8: Maintenance

    Clean the Turbine MAINTENANCE During use, the turbine should be kept full of liquid to ensure that drying does not occur Verify Accuracy inside the turbine. If drying or caking should Before use, check the turbine’s accuracy and occur, the rotor will stick or drag, affecting verify calibration.
  • Page 9 Replacing the Batteries 1. Remove the corner screws from the meter face and lift the display electronics from the turbine. 2. Remove the batteries. 3. Check the battery terminals and remove any corrosion. 4. Install the new batteries and make sure the positive posts are positioned correctly.
  • Page 10: Troubleshooting

    TROUBLESHOOTING Symptom Probable Cause Corrective Action Meter is not accurate 1. Field Calibration not perform- Field calibrate again or select Factory ed properly Calibration. 2. Factory Calibration not suit- Perform a Field Calibration according to able for liquid being measured Calibration Section. 3.
  • Page 11: Specifications

    SPECIFICATIONS - TURBINE All data for A109GMA025NA1 and A109GMA100NA1 determined with 1 centipoise Kermac solvent test fluid at 70° F (21° C). Data for FTB385 is determined with water at 70° F (21° C). A109GMA100NA1 A109GMA200NA2 Models A109GMA025NA1 Size 1 inch Low Flow 1 inch 2 inch Linear Flow Range...
  • Page 12 SPECIFICATIONS continued Dimensions A109GMA025NA1 A109GMA100NA1 A109GMA200NA2 Models 1 inch Low Flow Size 1 inch 2 inch A = Height†: Inches 2.5 in. 2.5 in. 4.25 in. Centimeters 6.3 cm 6.3 cm 11.4 cm B = Width Inches 2.0 in. 2.0 in. 3.0 in. Centimeters 5.1 cm 5.1 cm 7.6 cm C = Length Inches 4.0 in.
  • Page 13: Parts & Accessories

    PARTS & ACCESSORIES Order Replacement Kit with the part number given here. Part Number Description FTB899-ORING O-Ring Field Installable Options and Accessories Model Number Description FTB790-RK Remote Display Kit Module FLSC790-P-ND Pulse Output for Models without Displays (-ND suffix) (open collector output) Except as noted, Options and Accessories are for Display Models only and only one Module may be installed per unit.
  • Page 16 M-5065 /1111...

This manual is also suitable for:

Ftb381Ftb383Ftb385

Table of Contents