Components; Control Panel Components - Westinghouse WGen5300s User Manual

Hide thumbs Also See for WGen5300s:
Table of Contents

Advertisement

Available languages

Available languages

COMPONENTS

COMPONENTS

CONTROL PANEL COMPONENTS

1
1. Run/Stop Switch: Push to Run position to start or
Stop position to shut the generator off.
2. Data Center: Toggle to show voltage, frequency,
total hour meter, and run/maintenance timer.
3. Voltage Selector Switch: Select 120 Volts or 240
Volts. Shut the generator OFF before switching
voltages.
4. 120/240 Volt AC, 30 Amp NEMA L14-30R Twist
Lock Receptacle: Receptacle can supply either
120V or 240V output.
5. 120 Volt AC, 30 Amp NEMA TT-30R Receptacle:
Receptacle can supply a maximum of 30 Amps.
DATA CENTER
Voltage:
Displays current voltage
output.
8 | Westinghouse Outdoor Power Equipment, LLC
2
3
Frequency (Hz):
Displays power output
frequency in Hertz.
Push the Mode button to cycle through
the data display modes.
Mode Button
4
10
9
6. 120 Volt AC, 20 Amp Duplex NEMA 5-20R
Receptacles: Receptacles can supply a maximum of
20 Amps.
7. 20 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the NEMA
5-20R receptacles to 20 Amps.
8. 30 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the TT-
30R receptacle to 30 Amps.
9. 22-Amp Circuit Breakers: Each circuit breaker
limits the current that can be delivered through
each 120 Volt leg on L14-30R to 22 Amps.
10. Ground Terminal: The ground terminal is used to
externally ground the generator.
Lifetime Hours:
Displays the lifetime run
hours.
6
5
8
7 7
Run Time/Maintenance:
Displays current run time.
Resets to zero when shut
down. Maintenance
reminder displayed
when required.

Hide quick links:

Advertisement

Table of Contents
loading