OPERATION
Neutral ground wire
4. Reinstall the alternator cover.
IMPORTANT: Apply a new "NEUTRAL UNBONDED"
Label over the "NEUTRAL BONDED TO
FRAME" label on the front of the control
panel.
HIGH ALTITUDE OPERATION
Engine power is reduced the higher you operate above sea
level. Output will be reduced approximately 3.5% for every
1000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at
altitudes over 5,000 ft. (1524 m). Operation without this
adjustment will cause decreased performance, increased
fuel consumption, and increased emissions.
DO NOT operate the generator at altitudes below 2,000 ft.
(762 m) with the high altitude kit installed. Engine damage
may occur.
High Altitude Carburetor Kit Part# 518965

VOLTAGE SELECTOR SWITCH

The 120V/240V selector switch, which gives the user the
ability to double the amperage in the generator for more
demanding applications. The voltage selector switches the
dual 120V AC windings of the generator to produce 120V
or 240V. If a 240V appliance is connected to the 4-prong
L14-30R receptacle, the switch must be in the "240V"
position. The 120V only outlets will not output power when
the Voltage Selector is in the 240V position.
Only change the Voltage Selector Switch with the
generator OFF. DO NOT switch the voltage while the
generator is running or powering appliances.
14 | Westinghouse Outdoor Power Equipment, LLC
Bonded jumper wire
NOTICE
WARNING

BEFORE STARTING THE GENERATOR

Verify that:
• The generator is placed in a safe, appropriate location.
• The generator is on a dry, flat, and level surface.
• The engine is filled with oil.
• All loads are disconnected.
Fire and explosion hazard. DO NOT move or tip the
generator during operation.

STARTING THE ENGINE

1. Verify that fuel is in the gas tank.
2. Verify voltage selector switch is in the desired vo
3. Turn the fuel selector switch on the control panel to
gasoline operation.
4. Turn the fuel tank valve to the ON position.
Note: If cold starting, move the choke lever to the ON
position.
5. Choose the starting method:
a. Push-Button Start: Push and hold the engine
START/STOP button for two seconds.
b. Recoil Start: Manually close the choke if the engine
is cold. Firmly grasp and pull the recoil handle slowly
until you feel increased resistance, then pull rapidly.
6. After starting, allow the engine to run for several seconds
then move the Choke lever to the fully OFF position.
DANGER
ON
OFF