Formax AutoSeal FD 1500 Plus Operator's Manual page 11

Table of Contents

Advertisement

TROUBLESHOOTING
Fold quality needs improving:
1. Make sure paper is squared and installed correctly. Side guides should be evenly
balanced and snug against the paper.
2. If folds are still incorrect, adjust fold plates (see fold plate adjustment on page 4).
Paper is not folding square (Skewing):
1. If paper pulls left or right, adjust the skew adjuster. To adjust the skew, turn the
skew adjuster (figure 9) left or right until the paper is feeding correctly.
Ready light is not illuminated and power is on:
1. Press the black button (figure 6) near the power cord inlet to reset the breaker.
Ready light is blinking red:
1. Check that the top cover is installed properly.
2. Check to be sure the photo-eye, before the metal sealer rollers, is clear of forms and/or
paper dust.
Figure 9
MyBinding.com
5500 NE Moore Court
Hillsboro, OR 97124
Toll Free: 1-800-944-4573
Local: 503-640-5920
7

Advertisement

Table of Contents
loading

Table of Contents