Overview Of Settings - BEA IXIO-DT3 User Manual

Opening & safety sensor for automatic sliding doors
Hide thumbs Also See for IXIO-DT3:
Table of Contents

Advertisement

OVERVIEW OF SETTINGS

BASIC
Back
More
PRESETTINGS
RAD: FIELDSIZE
small
RAD: OUTPUT
IR: IMMUNITY
IR: FREQUENCY
More
Back
ADVANCED
Back
More
RAD: IMMUNITY
radar
RAD: DIRECTION
off
RAD: HOLDTIME
0.5 s
IR: WIDTH
+
service
IR: NUMBER
mode
IR: PRESENCE TIME
motion
IR: OUTPUT
REDIRECTION
motion
SMART DAISY CHAIN*
FACTORY RESET
DOOR BELL*
More
Back
DIAGNOSTICS
ZIP CODE
all parameter settings in zipped format
(see application note on ZIP CODE)
ID #
unique ID-number
ERROR LOG
last 10 errors + day indication
IR: SPOTVIEW
view of spot(s) that trigger detection
IR: C1 ENERG
signal amplitude received on curtain 1
IR: C2 ENERG
signal amplitude received on curtain 2
0
1
2
3
shopping
critical
standard
street
env.
>
>
>
NO
NC
NC
NC
NO
NC
< 2.8 m
normal
high
low
Sensors mounted close to each other should
A
B
have a different frequency.
factory value
low
>
uni
bi
uni
PRM
1 s
2 s
3 s
service mode = no IR detection during 15 minutes (maintenance).
1
2
This value excludes conformity of the door system to EN 16005 and DIN 18650.
15 s
30 s
1
min
NC
NO
NC
NO
NC
NC
motion
motion
opening output is active in case of: 0 motion detection
or
and
presence
presence
off
1/2
2/2
1/3
off
0.05 s
0.10 s
0.25 s
4
5
6
7
factory values for radar immunity, IR immunity, IR number and redirection
increased immunities, 1 curtain
increased immunities, redirection = motion and presence
>
>
>
current
freq
NO
NO: normally open
NC: normally closed
NC
NC
NO
> 2.8 m
higher highest
normal
high
excludes conformity of the door system according to EN
16005 / DIN 18650. IR Immunity on values 4 or 5 is
incompatible with IR presence time on value 0
not allowed when the sensor is used in emergency exits
>
>
>
>
uni
uni
bi
PRM
AWAY
Shop
Shop
Shop
4 s
5 s
6 s
7 s
2
5
10
20 min 60 min infinite
min
min
min
current
freq
NO
NO: normally open
NC
NC
NO
NC: normally closed
1 motion or presence detection
2 motion and presence detection
1/2: 1
sensor in chain of 2; 2/2: 2
st
2/3
3/3
1/3: 1
in chain of 3; 2/3: 2
st
0.50 s 0.75 s
1 s
1.5 s
POWERSUPPLY
OPERATINGTIME
RESET LOG
PASSWORD
LANGUAGE
ADMIN
8
9
Freq : freq. in
no detection
>
large
(100 Hz)
current: current
**
Inv.freq.
output
Inv.freq.: freq. in
NC
detection (2.5Hz)
For conformity to EN 16005 or DIN 18650 at a
mounting height of 2.8 m or more, use values
6 and 7.
high
>
PRM: for persons with reduced mobility
AWAY: unidirectional motion away from sensor
shop: automatic adaptation of field size (small shops)
8 s
9 s
Always additionally adjust
the arrow position on the
sensor with a screwdriver.
min. value for DIN18650: 1 min
min. value for EN16005: 30 s
sensor in chain of 2
nd
in chain of 3; 3/3: 3
in chain of 3
nd
rd
full
partial: outputs are
partial
not reset
reset
reset
2 s
5 s
* Setting in combination with an accessory (see p. 1).
For more information see user's guide of accessory.
**Setting accessible via LCD only
supply voltage at power connector
power duration since first startup
delete all saved errors
LCD and remotre control password
(0000= no password)
language of LCD-menu
enter code to access admin mode
5

Advertisement

Table of Contents
loading

Table of Contents