Mounting And Wiring - BEA IXIO-DT3 User Manual

Opening & safety sensor for automatic sliding doors
Hide thumbs Also See for IXIO-DT3:
Table of Contents

Advertisement

IXIO-DT3: INSTALLATION GUIDE
1
MOUNTING & WIRING
Fixation is compatible with the ACTIV8.
2
RADAR OUTPUT CONFIGURATION
RELAY OUTPUT
NOT for emergency exits
FREQUENCY OUTPUT
for emergency exits
INVERTED FREQUENCY OUTPUT
for specific door operators (NOT for emergency exits)
CURRENT SOURCE OUTPUT
for emergency exits
3
RADAR OPENING IMPULSE FIELD
from 15° to 45°, default 30 °
2.2 m
4 m x 2 m (wide)
NO: normally open
NC: normally closed
field size: 9
immunity: 2
2.2 m
field size: 9
immunity: 2
+
-
*
*
**
***
* Depending on OUTPUT CONFIGURATION settings
** For compliance with EN 16005 and DIN 18650,
connection to door controller test output is required.
***Current source output for emergency exits
YE/BK +
WH/BK -
from -15° to 15°, default 0°
2 m x 2.5 m (narrow)
The size of the detection field varies according to the mounting height of the sensor.
In emergency exits the full door width must be covered.
GREEN
POWER SUPPLY
BROWN
YELLOW
OPENING INPUT
WHITE
PINK
GREY
SAFETY INPUT
RED
TEST
BLUE
OUTPUT
YE/BK +
OPENING INPUT
WH/BK -
FOR CURRENT
SOURCE
OR
field size: 9
immunity: 2
2.2 m
field size: 9
immunity: 2
2.2 m
3