Switching The Rx Gain States; Receiver Diagnostic Signal Tracing - Nokia 2366i Rf Description And Troubleshooting

Mobile terminals
Hide thumbs Also See for 2366i:
Table of Contents

Advertisement

Nokia Customer Care

Switching the Rx Gain States

Use the RF Gen I/O dialog box to switch the gain state (Hi and Lo) for CDMA and AMPS
modes.
Hi Gain (Default)
State at power up

Receiver Diagnostic Signal Tracing

Use the following information to trace the received signal through the receiver chain:
• An RF signal generator is recommended; however, an Agilent call box 8960 may
also be used. For the 8960, press the CALL SETUP key, soft key Active Cell, and
then select CW.
• Inject a CW signal for PCS (1960.3 MHz) or Cell (881.82 MHz) at a fixed –65dBm
power level.
• Take measurements with the AAS-10 probe.
• Signal levels are approximate, and accuracy may be ± 2dB or more, depending on
position and grounding of probe.
Issue 2 - February 2007
Low Gain State
Cell
AMPS
(not used)
PCS
CDMA
Figure 23: RF Gen I/O dialog box