Category
Unit Options
SHDSL Options
T1 Options (T1 Mode Only)
61182210L1-5A
Table 4. Configuration Options List
Option
Data Mode
Local Management
Clock Source
Service State
External Port Alarms
Restore Factory Defaults
Firmware Upgrade
Change Password
SES CVC Threshold
SNR Margin Alarm
Threshold
Loop Attenuation Alarm
Threshold
ES 15 Minute Alarm
Threshold
SES 15 Minute Alarm
Threshold
UAS 15 Minute Alarm
Threshold
CVC 15 Minute Alarm
Threshold
LOSWS 15 Minute Alarm
Threshold
Line Coding
Framing Mode
Idle Pattern
FDL Monitoring (ESF Mode
Only)
Issue 1, August 2003
Setting
For Data Type = T1, Data Rate can
be from 3 to 24 timeslots
(i.e. 200 kbps to 1.544 Mbps)
For Data Type = E1, Data Rate can
be from 3 to 32 timeslots
(i.e., 192 kbps to 2.048 Mbps)
1 = Disabled
2 = Enabled
1 = Internal
2 = External
1 = In Service
2 = Out of Service - Unassigned
3 = Out of Service - Maintenance
1 = Disabled
2 = Enabled
0 to 255 CVC's
0 = Disabled
1 to 15db = Alarm Threshold
0 = Disabled
1 to 127db = Alarm Threshold
0 = Disabled
1 to 900 Seconds = Alarm Threshold
0 = Disabled
1 to 900 Seconds = Alarm Threshold
0 = Disabled
1 to 900 Seconds = Alarm Threshold
0 = Disabled
1 to 65535 Errors = Alarm threshold
0 = Disabled
1 to 900 Seconds = Alarm Threshold
1 = AMI
2 = B8ZS
1 = Unframed
2 = SF
3 = ESF
00h to FFh
1 = Disabled
2 = Enabled
Default
Data Type = 1
Data Rate = 24
Enabled
Internal
Out of Service -
Maintenance
Disabled
50
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
B8ZS
ESF
7Fh
Disabled
7