Procedure
1.
Turn off the feed water to the filter by turning the by-pass valve
BY-PASS position*.
2.
Slowly turn the handle on the pressure relief valve
position**. Allow at least one minute for system to depressurize and to
minimize spillage.
3.
When depressurized, remove the filter sump
(when viewed from above) with two hands.
4.
Remove the new cartridge and all contents from the protective packaging, and
slide the bag over the used cartridge.
5.
Remove the used cartridge by turning it clockwise. Discard used cartridge with
the bag, or clean and store for reuse.
6.
Inspect and clean the sump seal and adapter O-ring, if necessary. Using the
included packet of silicone, lubricate entire seal, O-ring and the sealing
surface in the filter head
NOTE: USE A SILICONE LUBRICANT ONLY. The use of any other lubricant, including
a petroleum-based lubricant, to install the O-rings is not in accordance with
Kinetico's installation recommendations and may void the applicable Limited
Warranty.
7.
Install the new cartridge into the cartridge adapter by turning it counter-
clockwise until it stops
8.
Install the filter sump by turning it counter-clockwise until it stops. IMPORTANT!
Check alignment of arrows to assure proper assembly
9.
Turn the handle on the pressure relief valve to the CLOSED position
10. Turn on the feed water by slowly turning the by-pass to the GREEN, "IN
SERVICE" position*.
* Your by-pass valve may be different than the one illustrated.
** Pressure relief valve may be in a different location than illustrated. If necessary, contact
your Kinetico dealer for assistance.
NOTE: Filter styles vary, and yours may not be exactly as previously described.
a
r
dding
egenerant
Make sure your salt storage tank never runs out of regenerant. Refill regenerant
anytime before water is visible in the brine drum or softener cabinet (on cabinet
models). Use Kinetico Water Softener Salt, available from most Kinetico dealers,
or another quality brand. Some salts contain foreign particles which can cause
problems with your system, so be sure to use a quality grade of salt, processed
especially for use in water softeners. If you choose to use potassium chloride,
contact your local authorized Kinetico dealer to find out about the recommended
adjustments to your system. Your Kinetico dealer can also recommend or perform
a schedule of periodic maintenance. DO NOT USE ROCK SALT, as it often contains
significant levels of dirt or foreign matter.
4
.