Certifications; Specifications - Allen-Bradley 1788-EN2DNR User Manual

Ethernet/ip-to-devicenet linking device
Table of Contents

Advertisement

Chapter 2
Install the 1788-EN2DNROM Linking Device
16

Certifications

Certification (when product
(1)
is marked)
c-UL-us
CE
RCM
KC
EtherNet/IP
DeviceNet
(1) See the Product Certification link at

Specifications

Attribute
Temperature, operating
• IEC 60068-2-1 (Test Ad, Operating Cold)
• IEC 60068-2-2 (Test Bd, Operating Dry Heat)
• IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
Temperature, nonoperating
• IEC 60068-2-1 (Test Ab, Nonoperating Cold)
• IEC 60068-2-2 (Test Bb, Nonoperating Dry Heat)
• IEC 60068-2-14 (Test Na, Nonoperating Thermal Shock)
Temperature, surrounding air, max
Unit power supply
DeviceNet power
Enclosure type rating
Shock, operating/nonoperating
• IEC60068-2-27 (Test Ea, Unpackaged Shock)
Vibration
• IEC60068-2-6 (Test Fc, Operating)
Relative humidity
• IEC60068-2-30 (TestDb, Unpackaged Damp Heat)
(1)
Wiring category
(1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding
Guidelines, publication 1770-4.1.
Rockwell Automation Publication 1788-UM059B-EN-P - September 2015
Value
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584.
European Union 2004/108/EC EMC Directive, compliant with:
• EN 61000-6-4, Emission standard for industrial environment
• EN 61000-6-2, Immunity for industrial environment
• EN61326-1, Meas./Control/Lab., Industrial Requirements
• EN61131-2, Programmable Controllers (Clause 8, Zone A & B)
European Union 2011/65/EU RoHS, compliant with:
EN50581, Technical documentation
Australian Radiocommunications Act, compliant with:
• EN 61000-6-4; Industrial Emissions
Korean Registration of Broadcasting and Communications Equipment, compliant with:
• Article 58-2 of Radio Waves Act, Clause 3
ODVA conformance tested to EtherNet/IP specifications.
ODVA conformance tested to DeviceNet specifications.
www.ab.com
for Declarations of Conformity, Certificates, and other certification details.
1788-EN2DNROM
0...60 °C (32...140 °F)
-40...85 °C (-40...185 °F)
60 °C (140 °F)
24V DC SELV/PELV (-15...20%)
100 mA @ 24V DC, max
24V DC SELV/PELV
20 mA @ 24V DC, max
Meets IP67 and UL Type 4/4X
Use dust caps on unused switches and connectors
30 g
5 g @ 10...500 Hz
5...95% noncondensing
3 - on USB ports, 2 - on power ports, 2 - on communication ports

Advertisement

Table of Contents
loading

This manual is also suitable for:

1788-en2dnrom

Table of Contents