3.0 OPERATION

CAUTION: If you smell gas during the lighting procedure,
immediately shut off the gas supply until the leak has been
corrected.
WARNING: In the event of main burner ignition failure, a 5 minute
purge period must be observed prior to re-establishing ignition
source.
WARNING: In the event you smell gas, shut down equipment at the
main shut off valve and contact the local gas company or gas
supplier for service.
GAS CONTROL INSTRUCTIONS
The units do not require "lighting" the pilot with a match.
A. Lighting
1. Turn thermostat to "OFF" position and power switch to "OFF" position.
2. Open control panel access door located on right side at bottom.
3. Turn dial on combination gas control to "ON" position by rotating control dial counter-
clockwise. NOTE: Any gas service valves exterior to the unit must be open.
4. Turn power switch to "ON" position.
5. Set "COOK TEMP" to desired setting. The red "COOKING" pilot will be on until desired
setting has been reached.