5.0 MAINTENANCE

Contact the factory, the factory representative or a local service company to
WARNING: Disconnect the power supply to the appliance before
cleaning or servicing.
Daily:
1. Wash exposed cleanable areas.
Monthly:
1) Clean around burner air mixers and louvered panels if grease or lint have accumulated.
TWICE A YEAR: (minimum)
Have an authorized service person clean and adjust the unit for maximum
performance.
It is NOT RECOMMENDED to use cleaning agents that are corrosive.
Use of cleaning agents that contain chloride, acids or salts are corrosive and may cause pitting
and corrosion when used over a period of time; this will reduce life of the appliance.
Should pitting or corrosion occur this is not covered by warranty.
Follow the recommended cleaning instructions. Use a mild detergent, warm water and rinse
thoroughly.
Never spray water into electric controls.
NOTICE: Draw-off valve has a vulcanized rubber coated stem for better sealing.
Do not over tighten. This may cause the rubber to pull away from stem and
permanently damage it. This is not covered under warranty.
perform maintenance and repairs.