Download Print this page
Eaton Metalux FP Panel Instructions Manual

Eaton Metalux FP Panel Instructions Manual

Advertisement

Available languages

Available languages

Quick Links

IB519062EN
FP Panel Instructions
Instructions pour panneau FP
Instrucciones del panel FP
IMPORTANT: Read carefully before installing fixture.
Retain for future reference.
WARNING
Risk of fire, electrical shock, cuts and or other casualty
hazards. This product must be installed in accordance
with the applicable installation code by a qualified
electrician or a person familiar with the construction
and operation of the product and the hazards involved.
Eaton assumes no responsibility for claims brought
about by improper or careless installation or handling
of this product.
ATTENTION
Receiving Department: Note actual fixture description
of any shortage or noticeable damage on delivery
receipt. File claim for common carrier (LTL) directly
with carrier. Claims for concealed damage must be
filed within 15 days of delivery. All damaged material,
complete with original packing must be retained.
CAUTION
Edges May Cut. Handle with care.
• Connect fixture to a 120/277 volt, 60 Hz power source. Any other connection voids the warranty.
• This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly
approved by the manufacturer could void the user's authorization to operate this equipment.
Risk of burn. Disconnect power and allow fixture to
cool before maintenance.
Risk of Fire and Electric Shock. If not qualified, consult
an electrician.
Ground screw provided in proper location. Do not
relocate.
Risk of Electric Shock. The light source contained
in this luminaire shall only be replaced by the
manufacturer or his service agent or a similar qualified
person.
Use 16-18 AWG solid or stranded wire for push-in
terminals.
CAUTION
WARNING
Metalux
CAUTION
WARNING
NOTICE
CAUTION
NOTICE

Advertisement

loading
Need help?

Need help?

Do you have a question about the Metalux FP Panel and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton Metalux FP Panel

  • Page 1 NOTICE Eaton assumes no responsibility for claims brought about by improper or careless installation or handling Ground screw provided in proper location. Do not of this product.
  • Page 2 (Fig. 3). If using a battery backup system remove driver cover plate to access LED load wires and follow battery backup wiring instructions (Fig. 5). Ensure driver cover plate is reinstalled after wiring. Figure 3. FP Panel Instructions IB519062EN www.eaton.com...
  • Page 3 To clean fixture use a small amount of water on a cloth and wipe the lens. Do not use chemicals on the lens as this could cause damage. 10. Turn breaker on. Use wall switch to verify light turns on. FP Panel Instructions IB519062EN www.eaton.com...
  • Page 4 électricien qualifié ou une personne à l'aise avec la MISE EN GARDE construction et le fonctionnement du produit ainsi qu'avec les dangers potentiels. Eaton n'assume aucune Risque de brûlures. Mettez l’alimentation électrique hors tension et laissez refroidir le luminaire avant de le manipuler responsabilité...
  • Page 5 N’utilisez pas de produits chimiques abrasifs pour nettoyer la lentille, car ces produits peuvent l’endommager. 10. Enclenchez le disjoncteur. Utilisez l’interrupteur mural pour vous assurer que le luminaire s’allume. Figure 4. Instructions pour panneau FP IB519062EN www.eaton.com...
  • Page 6 Riesgo de quemadura. Desconecte la alimentación y deje que la luminaria se enfríe antes de cambiar la bombilla o instalación aplicable. Eaton no se responsabiliza por los reclamos presentados respecto de la instalación manipular la luminaria.
  • Page 7 No utilice químicos en los lentes porque podrían dañarlos. 10. Active el disyuntor. Utilice el interruptor de la pared para verificar que la luz se encienda. Imagen 4. Instrucciones del panel FP IB519062EN www.eaton.com...
  • Page 8 Warranties and Limitation of Liability Please refer to www.eaton.com/LightingWarrantyTerms for our terms and conditions. Garanties et limitation de responsabilité Veuillez consulter le site www.eaton.com/LightingWarrantyTerms pour obtenir les conditions générales. Garantías y Limitación de Responsabilidad Visite www.eaton.com/LightingWarrantyTerms para conocer nuestros términos y condiciones.

This manual is also suitable for:

Metalux 22fp3250cMetalux 24fp4750cMetalux fpsurf22Metalux fpsurf24