Direction For Long Term Storage; Electric Wiring - Kubota D1503-M-E3 Operator's Manual

Hide thumbs Also See for D1503-M-E3:
Table of Contents

Advertisement

24
MAINTENANCE
(1) Thick cable red (+)
(2) Battery case
(3) Earth cable black (-)
(1) Plug
A Connect the charger positive (+) terminal to the
battery positive (+) terminal, and negative (-) to the
negative (-).
A When disconnecting the cable from the battery, start
with the negative (-) terminal first.
When connecting the cable to the battery, start with
the positive (+) terminal first.
If reversed, the contact of tools on the battery may
cause a short.
BDirection for long term storage
1. When storing the engine for long periods of time,
remove the battery, adjust the electrolyte to the proper
level, and store in a dry and dark place.
2. The battery naturally discharges while it is stored.
Recharge it once a month in summer, and every 2
months in winter.
(A) "HIGHEST LEVEL"
(B) "LOWEST LEVEL"

ELECTRIC WIRING

To avoid personal injury:
C Shorting of electric cable or wiring
may cause a fire.
A Check to see if electric cables and
wiring are swollen, hardened or
cracked.
A Keep dust and water away from all
power connections.
Loose wiring terminal parts, make
bad connections. Be sure to repair
them before starting the engine.
Damaged wiring reduces the capacity of electrical parts.
Change or repair damaged wiring immediately.