Maintenance Reserved To A Professionally Qualified Engineer - Intec 22201 Operating And Maintenance Manual

Air-hydraulic
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
EN
3. Let all the air flows out of the dowel until the oil starts to come out. If necessary, push the piston downwards and then
close the dowel again.
5. Let all the air out from the dowel and continue until oil starts coming through and then close the dowel.
8. Move the pistons back in completely and check oil level.
9. Try to operate the jack without any load and if the piston lowers in jerks repeat the procedure at least 2 or 3 times.
MAINTENANCE RESERVED TO A PROFESSIONALLY QUALIFIED
ENGINEER
Having to carry out maintenance or overhauling, use exclusively genuine spare parts to ensure the utmost reliability for the
jack.
PROBLEMS
Solutions
THE MOTOR WILL NOT START, OR IT RUNS BADLY.
- Check that the air supply line is not choked.
- If the pistons fail to move up, the pump could be empty. Completely lower the pistons by means of the descent
control and subsequently pressing with your hand, once the pistons have been lowered, press the up and down
commands a few times alternately. This will enable the pump to recharge.
- If the pistons are already completely lowered and the lifting command is not working, the pump will have to be
recharged according to the following procedure:
1. Connect the jack to the compressed-air circuit
2. Loosen the screw
POS. 7 A00388
POS. 7 A00388
3. In place of the screw just removed, screw on a pipe with compatible coupling.
4. Blow a small quantity of air inside the tank through the pipe just fitted and, at the same time, operate the lifting
command.
5. If, when the lifting command is operated, the pistons also move up without blowing air into the tank, the pump has
recharged and you can proceed to the next step. Otherwise, repeat the operations illustrated at the previous point.
6. Allow the pistons to move completely up by operating the lifting command. If the pistons move in jerks, the
bleeding procedure will have to be performed (see "Maintenance reserved to the end user").
7. Let the pistons re-enter being careful to leave the large piston
8. Remove the pipe fitted at point (3), and re-tighten the screw
9. Fully lower the large piston
THE JACK DOES NOT LIFT THE LOAD.
The pump unit will have to be replaced
THE JACK LIFTS, BUT COMES DOWN UNDER THE LOAD.
The block unit will have to be replaced
POS. 3 A00388
POS. 3 A00388
manually.
POS. 3 A00388
POS. 3 A00388
out by 4 cm.
POS. 7 A00388
POS. 7 A00388
15

Advertisement

Table of Contents
loading

Table of Contents