USE

- Expressly observe the safety rules already described in this manual.
1) Position the jack under the supports as described in the manual of the vehicle the manufacturing company is not
responsible for any break or damage to the lifted vehicle or to persons or property due to an incorrect use of the
jack.
2. By pressing key A on the control block the lifting function is activated. DWG. 12
3. By pressing key B on the control block the lowering function is activated. DWG. 12 In the absence of any load, the
pistons do not drop completely. Lower them manually to complete the descent.
4. After lifting the load, it is absolutely essential to rest it on the support stands before doing any work under it.
REMEMBER THAT THE JACK IS A LIFTING DEVICE AND NOT A SUPPORTING DEVICE!!
- The operator's employer will have to provide the necessary training and furnish the necessary information about
the pumping and shifting forces.
- Before working with the jack, it is advisable to perform a few operations with no load in order to acquire the
sensitivity necessary to work safely with the jack.
- When the jack is not used, always keep the pistons lowered
IMPROPER USE
The air-hydraulic jack has been designed and made to lift transport vehicles. Any other use of the jack, such as for
instance lifting and/or moving persons, is considered to be definitely improper. All use of the jack not in conformity with the
safety rules listed in this manual is considered to be improper use.

WARRANTY

This jack is covered by a 12-month warranty starting from the date the jack leaves our factory unless the warranty has
been activated on-line; this covers all manufacturing defects but not transport expenses, defects caused by improper use
or damage suffered during transport. For more details please see the warranty card attached to this manual.

MAINTENANCE OPERATIONS TO BE PERFORMED BY THE USER

- To ensure your jack a long life it is advisable to clean the pistons externally once a fortnight.
- Check the level of oil in the tank at least twice a year.
CHECK THE OIL LEVEL
The maximum quantity of oil in this jack is 0.55 L. Compatible oil: ATF DEXRON IID
Please follow the steps listed here to check the oil level:
1. Bleed off the air (see procedure in the next section)
2. Loosen the screw
POS. 7 A00388
POS. 7 A00388
3. If the oil fails to come out
The level must be at the height of screw
4. If oil does come out, let the excess quantity drain off until the right level is reached (see point 4).
5. Re-tighten the screw
POS. 8 A00388
POS. 8 A00388
re-tighten the screw
POS. 7 A00388
POS. 7 A00388
AIR BLEEDING
Each time the jack is serviced, removing and refitting parts connected to the tank and motorpump, it is advisable to bleed
off all air. Bleeding phases:
1. The pistons must be moved out completely.
2. Loosen the dowel
POS. 9
POS. 9
14
and then the screw
POS. 8 A00388
POS. 8 A00388
once the screw has been loosened, the level is too low. In this case, add oil.
POS. 8 A00388
POS. 8 A00388
. Operate the lifting control and allow the pistons to move up by about 4 cm, then
exploded drawing
A00388
A00388
POS. 8 A00388
POS. 8 A00388
(see DWG 13)
.
inside the piston
POS. 2 A00388
POS. 2 A00388
EN