Stanley PAC 520 Quick Start Manual page 7

Input controller & output controller

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
One-Touch™ Test Mode
Test
Normal
Operation
Hold down One-Touch™ button for less than
2 seconds.
One-Touch™
View Mode
Note: Automatically exits after 2 minutes.
CAUTION:
Disconnect any output relays that should not be triggered before entering
Hold down One-Touch™ button for 2 to 4
secs.
One-Touch™
Trigger each input sensor in turn and ensure
Active Mode
that the LEDs indicate the correct state.
Note: The controller will operate
unconfigured and no system
communications will occur.
Hold down One-Touch™ button for less than
2 seconds. One-Touch™ Test mode will
Exit One-Touch™
automatically be timed out after 1 hour,
Active Test mode
power up or power down.
Action
- 7 -
Observation
GREEN system status LED flashes at normal rate.
RED and GREEN input status LEDs off.
GREEN output status LED off.
GREEN system status LED flashes at twice normal
rate.
Unconfigured system:  All RED LEDs will flash
briefly three times and test mode is exited.
Configured system (expected)
RED LED = tamper state.
GREEN LED = active state/normal output.
GREEN LED off = non-active state/unconfigured
input.
View mode is intended for a configured system. See help for
more information.
Active mode.
GREEN system status LED flashes faster than
normal.
The first change in state will be latched and the display for that
input will not change until test mode is exited.
2-STATE
Green - Red
N/A
N/A
Input open
Input closed
3-STATE NO
Green - Red
N/A
Input open
Input closed
Input open tamper
GREEN output LED is on/off for a 5 second cycle
(relays active/inactive)
>
>
GREEN flashes at normal rate again.
All other status LEDs off.
4-STATE
Input open
Input closed
Input open tamper
Input tamper short
3-STATE NC
N/A
Input closed
Input open
Input tamper short