VR8200, VR4200
SPECIFICATIONS • ORDERING INFORMATION
IMPORTANT: The specifications given in this publica-
tion do not include normal manufacturing toler-
ances. Therefore, this unit may not exactly match the
listed specifications. Also, this product is tested and
calibrated under closely controlled conditions, and
some minor differences in performance can be ex-
pected if those conditions are changed.
SUPER TRADELINE MODELS
SUPER TRADELINE
able on TRADELINE or standard models, and are designed
to replace a wide range of Honeywell and competitive
controls.
SUPER TRADELINE model specifications are the
same as those of standard models except as noted below.
SUPER TRADELINE MODEL AVAILABLE: VR8200A
Continuous Pilot Dual Automatic Combination Gas
Control. Models for natural or LP gas.
ADDITIONAL FEATURES:
• Combination 1/4 inch quick-connect and screw ter-
minals (includes convenience terminals).
• One 3/8 inch bushing.
• One 3/4 inch straight flange assembly (with O-ring
and screws).
• One tool for flange hex screws.
• One pilot compression fitting.
• One Q340A 36-inch thermocouple with adapters and
clip.
TRADELINE MODELS
TRADELINE models are selected and packaged to
provide ease of stocking, ease of handling and maximum
replacement value. TRADELINE model specifications
are the same as those of standard models except as noted
below.
TRADELINE MODEL AVAILABLE: VR8200A Con-
tinuous Pilot Dual Automatic Combination Gas Con-
trol. Models for natural or LP gas.
ADDITIONAL FEATURES:
• Combination 1/4 inch quick-connect and screw ter-
minals (includes convenience terminals)
• One 3/8 inch bushing
When purchasing replacement and modernization products from your TRADELINE
price sheets for complete ordering number, or specify—
1. Order number, SUPER TRADELINE or
TRADELINE if desired.
2. Natural or LP gas.
3. Step pressure on step-opening control.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1. Your local Honeywell Residential and Building Controls Sales Office (check white pages of your phone directory).
2. Residential and Building Controls Division Customer Satisfaction
Honeywell Inc., 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386 (612) 951-1000
In Canada—Honeywell Limited/Honeywell Limitée, 740 Ellesmere Road, Scarborough, Ontario M1P 2V9. International Sales
and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan,
Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0046—4
®
controls offer features not avail-
• One 3/4 inch straight flange assembly (with O-ring
and screws)
• One tool for flange hex screws
• One pilot compression fitting
STANDARD MODELS
MODEL: VR8200 and VR4200 Continuous Pilot Dual
Automatic Valve Combination Gas Controls. For use
in standing pilot appliances. See Table 1 for model

specifications.

SUPPLY VOLTAGE:
VR4200: 120 Vac, 60 Hz.
VR8200: 24 Vac, 60 Hz.
(50/60 Hz models available on request.)
POWER UNIT:
Hold-in current: 300 mA maximum.
Drop-out current: 250 to 90 mA.
THERMOCOUPLE:
Nominal output: 30 mV (0.018 ohms).
Open Circuit Turndown Voltage: 2 mV.
ELECTRICAL CONNECTIONS (2): 1/4 inch male quick-
connects. Two convenience terminals on top of control
(optional). Terminal block color-coded beige.
THERMOSTAT HEAT ANTICIPATOR SETTING:
VR4200: 0.1A
VR8200: 0.5A
TYPE OF GAS: VR8200 and VR4200 set up for natural
gas includes a 393691 LP Conversion Kit. Kit for
conversion from LP to natural gas is available for stan-
dard and slow opening models. See Accessories.
CAPACITY: 130 feet
based on 1000 Btu/feet
at 1 inch water column pressure drop [37.3 MJ/meters
0.64 specific gravity natural gas at 0.25 kPa pressure
drop].
Maximum regulated capacity is 200 feet
3
[5.7 meters
/hour]. Minimum regulated capacity is
3
20 feet
/hour [0.6 meters
in Table 2 to convert to capacities for other gases.
Minimum regulated capacity is 40 feet
propane.

Ordering Information

®
wholesaler or your distributor, refer to the
4. Convenience terminals, if desired.
5. Accessories, if desired.
6. Order separately: pilot burner, thermocouple, transformer,
limit controller, and thermostat or controller as required.
2
Specifications
3
3
/hour [4.2 meters
/hour]. Capacity is
3
, 0.64 specific gravity natural gas
3
/hour]. Use conversion factors
3
/hour for
3
,
3
/hour