3.5.3.
RAM-53NE3F
Whichever indoor units are installed, cooling and heating capacity depends on how many and which indoor units are operating at
the same time.
[1] Capacity loss due to white frost and defrost operation is not included.
POSSIBLE
COMBINATIONS
TOTAL
CAPACITY
TO OPERATE
(kW)
RATING(kW) (RANGE)
1.5
1.5
(1.00-1.60)
1.8
1.8
(1.50-2.00)
2.5
2.5
(1.50-2.80)
3.5
3.5
(1.50-3.90)
5.0
5.0
(1.50-5.60)
1.5+1.5
3.0
(1.50-3.50)
1.5+1.8
3.3
(1.50-3.50)
1.5+2.5
4.0
(1.50-4.00)
1.5+3.5
5.0
(1.50-5.20)
1.5+5.0
6.5
(1.50-6.00)
1.8+1.8
3.6
(1.50-5.90)
1.8+2.5
4.3
(1.50-5.90)
1.8+3.5
5.3
(1.50-5.90)
1.8+5.0
6.8
(1.50-5.90)
2.5+2.5
5.0
(2.00-5.50)
2.5+3.5
6.0
(2.00-6.00)
2.5+5.0
7.5
(2.00-6.00)
3.5+3.5
7.0
(2.00-6.00)
3.5+5.0
8.5
(2.00-6.00)
COOLING
OUTDOOR UNIT
TOTAL
INPUT
TOTAL
(W)
1.50
1.50
700
(350-800)
1.80
1.80
730
(350-800)
2.50
2.50
800
(350-900)
3.50
3.50
1030
(350-1200)
5.00
5.00
1300
(350-1700)
1.50+1.50
3.00
900
(500-1100)
1.50+1.80
3.30
930
(500-1130)
1.50+2.50
4.00
1000
(500-1300)
1.50+3.50
5.00
1100
(500-1710)
1.22+4.08
5.30
1200
(500-1710)
1.80+1.80
3.60
1300
(500-1150)
1.80+2.50
4.30
1300
(500-1550)
1.80+3.50
5.30
1350
(500-1710)
1.40+3.90
5.30
1450
(500-1710)
2.50+2.50
5.00
1500
(500-1710)
2.21+3.09
5.30
1550
(500-1710)
1.77+3.53
5.30
1600
(500-1710)
2.65+2.65
5.30
1600
(500-1710)
2.18+3.12
5.30
1600
(500-1710)
CAPACITIES AND SELECTION DATA
CAPACITY
AMPERE(A)
EER
RATING(kW)
(RANGE)
220V 230V 240V
3.2
3.1 2.9 2.14
2.00
(1.50-2.20)
3.4
3.2 3.1 2.47
2.50
(1.80-3.50)
3.7
3.5 3.4 3.13
3.40
(1.80-4.70)
4.7
4.5 4.3 3.40
4.30
(1.80-5.80)
6.0
5.7 5.5 3.85
5.80
(1.80-6.60)
4.1
4.0 3.8 3.33
2.00+2.00
(2.20-4.70)
4.3
4.1 3.9 3.55
2.00+2.50
(2.20-5.20)
4.6
4.4 4.2 4.00
2.00+3.40
(2.20-6.40)
5.1
4.8 4.6 4.55
2.00+4.30
(2.20-6.60)
5.5
5.3 5.1 4.42
1.48+4.82
(2.20-6.60)
6.0
5.7 5.5 2.77
2.50+2.50
(2.20-6.40)
6.0
5.7 5.5 3.31
2.50+3.40
(2.20-6.60)
6.2
5.9 5.7 3.93
2.32+3.98
(2.20-6.60)
6.7
6.4 6.1 3.66
1.75+4.55
(2.20-6.60)
6.9
6.6 6.3 3.33
3.15+3.15
(2.20-6.60)
7.1
6.8 6.5 3.42
2.78+3.52
(2.20-6.60)
7.3
7.0 6.7 3.31
2.16+4.14
(2.20-6.60)
7.3
7.0 6.7 3.31
3.15+3.15
(2.20-6.60)
7.3
7.0 6.7 3.31
2.51+3.79
(2.20-6.60)
3-37
HEATING
OUTDOOR UNIT
AMPERE(A)
TOTAL
INPUT
TOTAL
(W)
220V 230V 240V
[1]
2.00
850
3.9
3.7
(700-1100)
2.50
900
4.1
4.0
(700-1200)
3.40
1000
4.6
4.4
(700-1500)
4.30
1300
6.0
5.7
(700-1800)
5.80
1700
7.8
7.5
(700-1800)
4.00
1080
5.0
4.7
(800-1400)
4.50
1300
6.0
5.7
(800-1600)
5.40
1500
6.9
6.6
(800-1500)
6.30
1600
7.3
7.0
(800-2250)
6.30
8.6
8.3
1880
(800-2250)
5.00
1450
6.7
6.4
(800-2000)
5.90
1500
6.9
6.6
(800-2250)
6.30
1620
7.4
7.1
(800-2250)
6.30
1800
8.3
7.9
(800-2250)
6.30
7.3
7.0
1600
(800-2250)
6.30
8.6
8.3
1880
(800-2250)
6.30
8.6
8.3
1880
(800-2250)
6.30
8.6
8.3
1880
(800-2250)
6.30
8.6
8.3
1880
(800-2250)
COP
3.6 2.35
3.8 2.78
4.2 3.40
5.5 3.31
7.2 3.41
4.5 3.70
5.5 3.46
6.3 3.60
6.7 3.94
7.9 3.35
6.1 3.45
6.3 3.93
6.8 3.89
7.6 3.50
6.7 3.94
7.9 3.35
7.9 3.35
7.9 3.35
7.9 3.35