Hitachi MULTIZONE RAM-40NE2F Technical Catalogue page 49

Table of Contents

Advertisement

CAPACITIES AND SELECTION DATA
3-36
Indoor unit model
RAK-15QEF
RAK-18REF
RAK-25REF
RAK-35REF
RAK-50REF
*Two units must be connected to the outdoor unit to avoid water condensation and result in water splash.
*One unit values are for one unit operation with two indoor connected.
*Total nominal cooling capacity should not be more than 8.8kW
Capacity (kW)
Nominal cooling
at single unit operation
capacity (kW)
Cooling
1.5
1.00-1.60
1.8
1.50-2.00
2.5
1.50-2.80
3.5
1.50-3.90
5.0
1.50-5.60
Suitable room size (m
At single unit operation
Heating
Cooling
1.10-2.20
8-12
1.80-3.50
8-12
1.80-4.70
11-17
1.80-5.80
16-24
1.80-7.20
23-24
2
)
Heating
9-11
9-11
14-18
17-22
23-29