Huawei UPS2000-G-3K-V1-DR Quick Manual

Hide thumbs Also See for UPS2000-G-3K-V1-DR:

Advertisement

Quick Links

UPS2000-G-3 kVA
Quick Guide (CTC)
Issue: 01
Date: 2019-03-15
1
Overview
Product
UPS
BoostLi Energy
Storage Module
PDU
Rectifier
UPS Front View
The UPS is working in ECO mode
only when the mains indicator and
bypass indicator are both on.
Model
UPS2000-G-3K-V1-DR
ESM-48100A1
-
R4850G2
Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
Weight
Dimensions (H x W x D)
32 kg
130 mm x 430 mm x 757 mm
190 mm x 442 mm x 560 mm
70 kg
(excluding mounting ears)
86 mm x 442 mm x 601.5 mm
9.7 kg
(excluding rectifiers)
≤ 2 kg
40.8 mm x 105 mm x 281 mm
No.
Name
1
LCD
2
Mains indicator
Battery indicator •
3
Bypass indicator •
4
5
Fault
indicator/INFO
button
6
Enter/Startup
button
7
Down button
8
Up button
9
ESC/Shutdown
button
1
Description
N/A
On: The UPS is working in
normal mode.
Off: The UPS is not working in
normal mode.
On: The UPS is in battery mode.
Off: The UPS is not in battery
mode.
Blinking: The remaining battery
capacity is less than 25%.
On: The UPS is in bypass mode.
Off: The UPS is not in bypass
mode.
Steady red: The UPS is faulty.
Blinking red: The UPS generates
an alarm.
Green: The UPS is running
properly.
Confirms settings, starts the UPS,
mutes the buzzer, or performs a
battery self-check.
N/A
N/A
Returns to an upper-lever menu, or
shuts down the UPS.

Advertisement

Table of Contents
loading

Summary of Contents for Huawei UPS2000-G-3K-V1-DR

  • Page 1 UPS2000-G-3 kVA Quick Guide (CTC) Issue: 01 Date: 2019-03-15 Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved. Overview Product Model Weight Dimensions (H x W x D) UPS2000-G-3K-V1-DR 32 kg 130 mm x 430 mm x 757 mm...
  • Page 2 UPS Rear View (1) AC input and AC (2) Battery terminal (3) Optional card slot (4) Port for a battery output terminal cover cover temperature sensor cover (5) Universal Serial Bus (6) Control area (7) Parallel ports (8) Maintenance (USB) port (security network (CAN) bypass port protection...
  • Page 3 Silk Indicator Color Status Description Screen Running indicator Green Steady on Communication is normal (including board startup, self-check, software loading, and board power-on when not loaded; excluding sleep when the power port or PWR port is energized). The ESM is in sleep mode. Blinking at 0.5 Hz The LCD user interface (LUI) is querying data.
  • Page 4: Installing Devices

    2. Use insulated tools during installation. 3. Only engineers certified by Huawei or its agents are allowed to install, commission, and maintain the UPS. Otherwise, personal injury or equipment damage may occur, and the UPS faults caused are beyond the warranty scope of Huawei.
  • Page 5: Installing Cables

    3. When the AC input or AC output changed, for details about how to change the input or output system, contact Huawei technical support. Do not power on the UPS directly. 4. Connect the UPS output power cable to the AC OUTPUT sL terminal.
  • Page 6 1. Install the UPS output short-circuit copper bar. UPS output busbar Short-circuit copper bar 2. Install cables. Wiring Diagram Battery cable AC output Battery power cable cable AC input power cable PDU rear (11) UPS output cable UPS rear Battery Battery cable UPS input...
  • Page 7 OT-6 mm -M4 terminal/OT-6 mm UPS output power Provided by 6 mm M6 terminal/OT-6 mm -M6 90° 2.8 N⋅m cable (sL/N/PE) Huawei terminal UPS input power OT-6 mm -M4 terminal/6 mm Provided by 6 mm 2.8 N⋅m cable (L/N/PE) OT terminal...
  • Page 8 (Optional) Connecting Cables to Optional Cards Dry Contact Card Typical Application Scenario Shutdown signals UPS faults Backfeed Battery undervoltage Bypass mode Customer Battery mode equipment Normal mode Dry Contact Definition Contact Report Criteria Reference (Default) The UPS is faulty, including: startup failure, battery fault, Contact a, lower rectifier fault, INV fault, internal...
  • Page 9: Verifying The Installation

    The battery voltage is greater than 46.5 V DC. Powering On and Starting the UPS User interface (UI) snapshots shown in this document correspond to V200R001C91SPC070 and are for reference only. If any UI changes are made, contact Huawei technical support to obtain the latest snapshots. Symbol...
  • Page 10 Powering On the UPS Start Check that the UPS has passed all check items described in chapter 6 "Verifying the Installation". Press and hold the MANUAL ON/OFF button on each lithium battery for at least 5s and less than 15s to activate the lithium battery. No: Start the UPS in battery mode.
  • Page 11 Set Language (default: English), System Parameters, and Battery Parameters. 1. The preset password is 000001, used to enter the Settings menu. 2. The default feature code is 999999, used to restore the preset password. Setting the Input Power Limiting Choose Settings > Battery Parameters, and set Input power limiting based on the actual situation.
  • Page 12: Shutting Down The Ups

    Starting inverter Perform startup operations: On the standby screen, hold down for more than 5 seconds. Release the button when you hear a beep sound. The startup screen is displayed. After the UPS starts successfully, it enters normal mode. After the system runs properly, close the UPS downstream AC output switch to start loads.
  • Page 13 Measures: Disconnected the external battery charger, check whether the alarm is cleared. If not, contact Huawei technical support for repair. Batt. 0026-01 Minor Automat An alarm is Possible cause: The mains input is undervolt.
  • Page 14 UPS and Measure: Clean off the foreign objects system is not around the fan. If the alarm persists, affected. contact Huawei technical support for repair. Inverte 0060-04 Critical Power- The UPS shuts Possible cause: The inverter output is r fault down.
  • Page 15 (by a step of 100 W). Huawei Technologies Co., Ltd. Huawei Industrial Base, Bantian, Longgang Shenzhen 518129 People's Republic of China www.huawei.com...

Table of Contents