Wiring The Alarm Contact - Planet WGS-5225-8UP2SV Quick Installation Manual

Industrial l2+ 8-port 10/100/1ooot 802.3bt poe + 2-port 1g/2.5g sfp wall-mount managed switch with lcd touch screen
Table of Contents

Advertisement

Wire
Flat-blade screwdriver
The wire gauge should be in the range from 12 to 16 AWG.
Note

4.3 Wiring the Alarm Contact

The alarm contacts are in the middle of the terminal block connector as the picture
shows below. Inserting the wires, the Wall-mount Managed Switch will detect the
event status of the port or power failure and then forms an open circuit. The
following illustration shows an application example for wiring the alarm contacts.
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
V 1
V 1 +
V 2
V 2 +
Insert the wires into the fault alarm contacts.