Stuv 6 Series Specifications & Manufacturer Installation Manual

Advertisement

Quick Links

^ ^
STUV 6 FREESTANDING
SPECIFICATIONS &
MANUFACTURER
INSTALLATION GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for Stuv 6 Series

  • Page 1 STUV 6 FREESTANDING SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE...
  • Page 2 Congratulations on your purchase of the Stuv 6 Freestanding. This appliance should be installed and checked by a qualified professional. Ensure you have read the operation guidelines thoroughly prior to first use. For any questions or concerns please contact Oblica on 03 9416 0400.
  • Page 3: Dimensions & Technical Data

    1. DIMENSIONS & TECHNICAL DATA STUV 6 FREESTANDING - DIMENSIONS OF THE APPLIANCE AND THE FLOOR PLATE (OPTIONAL) View from the left Front view WEIGHT AND DIMENSIONS: Firebox external dimensions W700 x H725 x D430mm Firebox weight 95Kg Flue system Standard 6”...
  • Page 4 130mm 350mm 124mm 637mm* *-0/+10mm DIMENSIONS AND POSITIONS OF THE AIR INTAKES View from the left View from below Stuv 6 Freestanding 80mm 400mm 237*mm 175mm 350mm 50mm 263mm STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 4...
  • Page 5 CONNECTION TO THE COMBUSTION SMOKE OUTLET PIPE Smoke outlet towards the rear and corresponding finishing cover Smoke outlet upwards and corresponding finishing covers OPTIONS Ø80mm rear air connection kit Ø80mm air connection kit from below STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 5...
  • Page 6: Pre-Installation

    Combustible 100mm IMPORTANT: Frames must also be considered. Timber window frames must be treated as combustible surfaces (see 2.3). Aluminium frames can be treated as non-combustible surfaces (see 2.2). STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 6...
  • Page 7: Installation

    8” Outer Case 10” Outer Case CEILING RING 8” Flue 8” Flue 6” Active Flue Fireplace outlet NOTE: The active flue must go around the fireplace outlet on the outside. STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 7...
  • Page 8 The top of the flue must be 900mm above the roofline. Alternatively, there must be a minimum distance of 3 meters from any higher section of roof. > 3 m – > 900 cm – > 900 cm > 900 cm – – STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 8...
  • Page 9 FLOOR PROTECTOR LAID ON JOIST 300mm 300mm Combustible Insulative board (6mm) floor (eg. timber) Combustible + non combustible finish Insulative board (6mm) 930mm floor (eg. timber) + non combustible finish 930mm Joist Joist STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 9...
  • Page 10: Top View

    Non combustible finish floor (eg. timber) floor (eg. timber) (eg.tiles) (eg.tiles) Concrete Concrete TOP VIEW Floor protector Combustible floor Floor protector (eg: Timber) 300mm Combustible floor 930mm (eg: Timber) 300mm 930mm STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 10...
  • Page 11 > Remove the fixing screw from the crosspiece [diagram 2]. > Dismantle the pallet structure using a crowbar [diagram 3]. > Break the fixing lug with pliers [diagram 4]. STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 11...
  • Page 12: Checking The Contents

    (floor plate, outside air - A can of paint for touch-ups, connections,...), they are arranged around - A black Stuv glove to give to the end user, the stove or its packaging. - Two pairs of white gloves for handling the...
  • Page 13 To remove the rear facings, remove the 4 upper nuts [Figure 6], then loosen the 2 lower nuts and slide the facings sideways out of the groove [Figure 7&8]. STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 13...
  • Page 14 4. INSTALLATION DISMANTLING AND MOVING STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 14...
  • Page 15: Air Intake

    If you use our standard 80mm flexible duct, we recommend a maximum length of 2m and no more than 4 bends. If you do not follow these recommendations, you will need to compensate by having a larger diameter and/or a more flexible tube. Make sure you do not squash the duct. STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 15...
  • Page 16 If you choose to get the air for combustion through the frame make sure you follow these simple steps: 1. Remove the head from the Damper. 2. Remove the 2 side screws. 3. Remove the 2 plates and the spring. 4. Put the Damper Head back on. STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 16...
  • Page 17 > Place the foam gasket in the nozzle on the air box, rotate the nozzle to lock it [diagram 2]. > Attach the hose to the nozzle using a hose clamp [diagram 3 STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 17...
  • Page 18 [diagram 4]. > Saw off the first junctions of the pre-cut lid from the rear walls using a hacksaw then break the following [diagram 5 & 6]. STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 18...
  • Page 19: Flue Connections

    > Use a temperature resistant glue for bonding the finishing rosette [diagram 5]. > Saw the first junctions of the precut cover using a hacksaw then break the following [diagram 6-8]. STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 19...
  • Page 20 6. FLUE CONNECTIONS TOP FLUE CONNECTION Caution: Attach the nozzle to the fireplace using self-tapping screws. Three holes are fitted for this purpose in the cast iron flange [diagram 5]. STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 20...
  • Page 21 7. REASSEMBLY REASSEMBLY OF SIDE FACINGS AND DOOR STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 21...
  • Page 22 Please refer to the instructions for use. Once the stove is installed, give the instructions back to the user. Fill in the warranty certificate with them (online), the acceptance report and the installation report, and recommend that they send this back to the manufacturer or importer. STUV 6 FREESTANDING | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE PAGE 22...
  • Page 23: Operation

    WARNING: • The Maximum load capacity of the STUV 6 Freestanding is 5 kg of Hardwood/hour. • Overloading the unit may result in damaging the heater and voiding the warranty. • Misuse may lead to unhealthy and environmentally harmful emissions.
  • Page 24: Test Report

    AS/NZS 4012, AS/NZS 4013 (2014). CONCLUSION: The Stuv 6 Insert solid fuel burning appliance complies with the requirement of a combined efficiency of not less than 60% and a particulate emissions factor of not greater than 1.5g/kg of hardwood that complies to AS/NZS4014.