and Channel Buttons
③ Time Code Button
④ Audio Meter Button
⑤ UMD Button
⑥ Multiview Layout Button
⑦ Full Screen Button
⑧ Lock Button
⑨ Knob
PC Control
You can control the Multiviewer via web browser. The default IP address of Multiviewer is 192.168.1.215.
- Switching an source to an window.
press buttons "IN, 1, OUT, 2" to switch source 1 signal to window 2.
- Switching an input to multiple windows.
Press buttons "IN, 1, OUT, 2, 4, 5" to switch source 1 signal to windows 2, 4, 5.
2) Switcher Mode
- Switching an input to an output.
press buttons "IN, 1, OUT, 2" to switch input 1 signal to output 2.
- Switching an input to multiple outputs.
Press buttons "IN, 1, OUT, 2, 4, 5" to switch input 1 signal to output 2, 4, 5.
3) Note
- Channel button over 10 need two buttons to combine,
For example, 10= [10+] [10+], 11=[10+] [1], 12=[10+][2], ... ,16=[10+][6]
- The OUT button indicator will automatically close after 8s. When it is off, you
only need to press the OUT button again to continue the unperformed switch.
Quick switch for Time Code overlays ON/OFF
Quick switch for Audio Meter bars ON/OFF
Quick switch for UMD overlays ON/OFF
Quick switch between 20 kinds of multiviewer layouts
Press this button to activate the full screen mode; then select channel button to
solo any inputs as full screen
Lock or unlock, press the button to Lock or unlock front panel buttons
Controls the menu.
Turn anticlockwise=menu Up , Turn clockwise=menu down, Press down = Enter