Page 1
VZ-MV1602-SDI User Manual INSTRUCTION MANUAL VER 1.1 2018.8.6...
Page 2
VZ-MV1602-SDI User Manual Instruction Manual Compact 1RU 16 Channel 3G-SDI VZ-MV1602-SDI Multiviewer with 16×16 3G-SDI Matrix Switcher This device is the perfect solution for a large broadcast project. One machine supports two modes, 16 channel SDI multiviewer mode and 16x16 SDI matrix switcher. The input signal detects SD, HD and 3G-SDI automatically. The video format of multiview outputs can be selected from total 9 formats from 720p to 1080p.
Page 3
VZ-MV1602-SDI User Manual Default Mode: Multiviewer Mode Connections SDI Video Input SDI Video Output Control 16×SD/HD/3G-SDI(75Ω BNC) 2×SD/HD/3G-SDI(75Ω BNC) Front panel button, PC software via LAN/RS-422 SDI Video Loop Output HDMI Video Output Standards SDI Auto Switching SDI Inputs Format Support Automatically detects SD, HD and 3G- (HD) 1920×1080p 60/59.94/50/30/29.97/25/24/23.98...
Page 4
Technical Specifications ① Inputs SDI inputs 1-16 ② Loop Outputs SDI loop outputs 1-16 ③ RS-422 Reserved for software control ④ LAN Software control and update Dual power connectors PS-1 & PS-2, ⑤ Power ⑥ Power Switch To turn on or off the device for power redundancy ⑦...
Technical Specifications Interfaces ① Inputs SDI inputs 1-16 ② Outputs SDI outputs 1-16 ③ RS-422 ④ LAN Reserved for PC software control PC software control and update Dual power connectors PS-1 & PS-2, ⑤ Power ⑥ Power Switch To turn on or off the device for power redundancy Note: The mode of Multiviewer and Switcher can be switched by PC software or knob menu.
Page 6
Technical Specifications and Channel Buttons - Switching an source to an window. press buttons “IN, 1, OUT, 2” to switch source 1 signal to window 2. - Switching an input to multiple windows. Press buttons “IN, 1, OUT, 2, 4, 5” to switch source 1 signal to windows 2, 4, 5. 2) Switcher Mode - Switching an input to an output.
Page 7
The matrix switcher will auto obtain an IP address, so you can scan the device directly by the control software. Method B) When connecting VZ-MV1602-SDI with a PC without DHCP. Please make sure that device and PC are in the same local area network, and set PC’s IP address to "192.168.1.xxx", except device’s default IP address 192.168.1.215, then press the "scanning"...
Technical Specifications Menu Control Main Menu Sub Menu Options Description Language Chinese/English Change the Language between Chinese and English LCD brightness 10-100 Set the brightness backlight between 10-100 Set the state of backlight,there are three mode for LCD ON/OFF Always/ Off/ Dim option: Always/Off/ Dim System LCD Sleep...
Technical Specifications Yellow/White/Gray/Violet Red/Light Blue/Light Green/Light Background Cyan/Light Background color setting Yellow/Transparent/HalfTrans/Blac k/Blue/Red/Magenta/Green/Cyan Return Back to the main menu Audio Source WIN1~WIN16 Select the audio source of multiviewer output Audio Meter 1~16 Select a certain window for audio meter setting CH1&CH2 CH3&CH4 CH5&CH6...
Technical Specifications Dimension Net Weight Gross Weight Standard 19” 1 rack unit 2.0kg 3.8kg Environmental Specifications Operating Temperature Storage Temperature Relative Humidity 0℃~60℃ -30℃~70℃ 0%~90% non-condensing What's Included Compact 1RU 16 Channel 3G-SDI Multiviewer with 16×16 3G-SDI Matrix Switcher DC 12V 5A Power Adapter × 2 Warranty 3 Year Limited Manufacturer's Warranty.
Page 11
16-CH SDI Multiviewer & Matrix Switcher API Guide V1.1 Part 1 Communication Mode I Interface: LAN Communication Protocol: UDP Broadcast Destination Port: 7000 Communication Mode II Interface: RS-422 Baud Rate: 9600 Parity Bit: NONE Data Bit: 8 Stop Bit: 1 Part 2 Format of Protocol Mode 2.1 Send from PC to Multiviewer (hex)
Page 12
Return from Multiviewer to PC Data Packet Value (hex) Byte Description 0xA5 Packet Header The beginning of data packet. 0x6C The length of the entire data packet from packet Data Length header to end (including the packet header and 0x0000~0xFFFF end).
Page 13
Turn on/off the OSD. OSD Enable 0x5d 1: ON, 0: OFF Turn on/off the audio alarm function Audio Alarm enable 0x56 1: ON, 0: OFF Turn on/off time code Time Code Enable 0x5e 1: ON, 0: OFF Change operating mode between Multiviewer and Switcher. Operating Mode 0x62 0:Multiviewer, 1: Switcher...
Page 14
Partial Parameter List esponse Format of Reading All Data of the Device’s Current Status 3.3.1 The r typedef struct unsigned char value:6; // output resolution unsigned char signal:1; //OSD enable 1 on, 0 off unsigned char res:1; //Reserved }Reso_Byte; typedef struct unsigned char uEn:1;...
Page 15
3.3.2 Multiview Output Layout List Layouts Value (hex) Note 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 1-16 Corresponding to each channel, total 16 full screen layouts. 0x09 0x0a 0x0b 0x0c 0x0d 0x0e 0x0f 0x10 Quad-split view 0x28 Audio meter, UMD, OSD inside...
Page 17
9 windows-3 With analog clock, 0x5c Audio meter, UMD, OSD outside Biggest window in the middle 9 windows-4 With analog clock 0x5d Audio meter, UMD, OSD outside Biggest window in the upper left corner 10 windows-1 0x64 Audio meter, UMD, OSD inside 10 windows-2 0x65 Audio meter, UMD, OSD outside...
Page 18
3.3.3 Output Resolution List Output Resolution Value (hex) 1080p60 0x07 1080p50 0x0b 1080p30 0x03 1080p25 0x0d 1080p24 0x05 1080i60 0x09 1080i50 0x01 720p60 0x0e 720p50 0x06 3.3.4 Audio Meter Channel List Channel Number Value (hex) CH 01&02 0x00 CH 03&04 0x01 CH 05&06 0x02...
Page 19
Part 4 Examples Following examples are through LAN port. Through serial port should change the interface byte Description: and recalculate the Checksum. All data are hexadecimal. CMD in red color words, data in green words. Every packet data is in couple, including Send and Return. Interface: LAN Method: UDP Unicast Destination Address: IP address of the multiviewer &...
Page 20
The Description of above Return: a5 6c 09 03 a1 ff 01 00 00 00 00 00 00 00 00 00 From packet header to reserve Command byte Response success Output layout value Definition of resolution, audio channel, and others overlay enables Input channel under multiviewer mode (Total 16 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10...