Appendix A: Modbus Address - ABB Comem DTI Instruction Manual

Temperature monitoring device
Table of Contents

Advertisement

TEMPERATURE MONITORING DEVICE COMEM DTI AND COMEM EDTI - INSTRUCTION MANUAL
26

Appendix A: MODBUS Address

Register
address
Operation for monitoring
0x280
0x281
0x282
0x283
0x288
0x289
0x28A
0x28B
0x290
0x291
0x292
0x293
0x258
0x259
0x25A
0x25B
Operations
Description
R
CH1 Instantaneous
Temperature [°C]
R
CH2 Instantaneous
Temperature [°C]
R
CH3 Instantaneous
Temperature [°C]
R
CH4 Instantaneous
Temperature [°C]
R
CH1 Maximum
Temperature [°C]
R
CH2 Maximum
Temperature [°C]
R
CH3 Maximum
Temperature [°C]
R
CH4 Maximum
Temperature [°C]
R
CH1 Diagnostic
R
CH2 Diagnostic
R
CH3 Diagnostic
R
CH4 Diagnostic
R
CH1 Instantaneous
Temperature &
Diagnostic [°C]
R
CH2 Instantaneous
Temperature &
Diagnostic [°C]
R
CH3 Instantaneous
Temperature &
Diagnostic [°C]
R
CH4 Instantaneous
Temperature &
Diagnostic [°C]
Notes
0x0000 Input is right
connected
0x0001 Input is shorted
0x0002 Input is open
0x0003 Input is failure
0x0000 Input is shorted
0x0001 Input is open
Real Value = Read Value (dec) - 25